background image

f.

Attach the motor leads to the termi-

nal block.  The motor is not polarity sensitive.

g.

Re-assemble the light and test for

proper operation.

2.

Series A Model 371 & 371L Rotating
Lights.

a.

Loosen and remove the retaining

band from the light.  Lift off the dome.

b.

Remove the three 1/4-20 KEPS nuts

that secure the base plate to the light housing and
remove the base.

c.

Disconnect the motor wires from the

terminal block.

d.

Remove the motor cover plate by

removing the two no. 6 screws that secure the plate
to the mounting base.  Remove the motor plate
assembly by removing the four no. 10 screws.

f.

Before installing the new motor,

crimp the provided ring terminals on the new motor
leads.

g.

Assemble the new motor plate assem-

bly to the mounting base making sure that the worm
on the motor shaft engages with the gear attached to
the lamp shaft.  Apply a small amount of light high

quality grease to the gear before re-installing the
motor cover plate.

h. Attach the motor leads to the termi-

nal block.  The motor is not polarity sensitive.

i.

Re-assemble the light and test for

proper operation.

II.

SERVICE.

The Federal factory will service your equipment

or provide technical assistance with any problems
that cannot be handled locally.

Any units returned to Federal Signal for service,

inspection, or repair must be accompanied by a
Return Material Authorization.  This R.M.A. can be
obtained from a local Distributor or Manufacturer’s
Representative.

At this time a brief explanation of the service

requested, or the nature of the malfunction, should
be provided.

Address all communications and shipments to:

FEDERAL SIGNAL CORPORATION
Electrical Products Division
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195

-2-

Содержание COMMANDER 371

Страница 1: ...and shipments to FEDERAL SIGNAL CORPORATION Electrical Products Division Service Department 2645 Federal Signal Drive University Park IL 60466 3195 MODEL 371 371L INSTRUCTION SHEET FOR COMMANDER MODE...

Страница 2: ...installation for integrity and proper operation Failure to follow all safety precautions and instructions may result in property damage serious injury or death to you and others I INSTALLATION A Unpac...

Страница 3: ...oceed as follows 1 Remove dome assembly by grasping the die cast ring attached to the dome and turning it counter clockwise 2 See figure 2 The lamp is locked in place with three 10 32 screws Remove th...

Страница 4: ...e clamping screw max tightening torque 7 0 in lbs 8 N m IMPORTANT Proper grounding of the light requires two connections to a solid earth ground 5 See figure 3 Connect earth ground to terminal block a...

Страница 5: ...e curved lamp retainer toward the front of the lamp Lift out the lamp 4 Install the replacement lamp by placing the edge of the lamp into the groove of the die cast lampholder Rotate the lamp so that...

Страница 6: ...A028 D Accessories Description Part Number Mounting bracket surface 371BRCKT Mounting bracket wall LWMB2 Mounting bracket corner LCMB2 Kit shock mount K8459A076C Conduit hub kit 3 4 NPT K8459138A Clos...

Страница 7: ...6 371 LIGHT ASSEMBLY PIPE MOUNT SURFACE MOUNT GASKET MOUNTING SURFACE 1 4 WASHERS DRILL 3 9 32 7 143 mm HOLES 1 4 SCREWS 1 NPT PIPE 290A3939 1...

Страница 8: ...7 DOME ASSEMBLY DIE CAST RING TURN DIE CAST RING COUNTER CLOCKWISE TO REMOVE LOCKING SCREW ADJUST LAMP TO DESIRED POSITION PIVOT SCREWS 2 290A3940 2...

Страница 9: ...8 DOME ASSEMBLY DIE CAST RING 2 8 7 m m GASKET GROUND SCREW MOTOR MOUNTING BASE SCREWS 10 HEX HEAD 3 TERMINAL BLOCK BASE TURN DIE CAST RING COUNTER CLOCKWISE TO REMOVE 290A3941 A A 3...

Страница 10: ...9 DOME ASSEMBLY DIE CAST RING TURN DIE CAST RING COUNTER CLOCKWISE TO REMOVE LAMP LAMP RETAINER LIFT UP SPRING CLIP AND ROTATE LAMP RETAINER FORWARD CONNECTOR LAMP TERMINALS 290A3942 4...

Страница 11: ...SERVICE INSTRUCTIONS FOR SHOCK MOUNT KIT FOR COMMANDER MODEL 371 LIGHTS Address all communications and shipments to FEDERAL SIGNAL CORPORATION Electrical Products Division 2645 Federal Signal Drive Un...

Страница 12: ...o routinely check the light installation for integrity and proper operation Failure to follow all safety precautions and instructions may result in property damage serious injury or death to you or ot...

Страница 13: ...h the provided nuts and lockwashers g Complete the installation of the light by following the appropriate sections in the instruction sheet that accompanied the device II SERVICE The Federal factory w...

Страница 14: ...Made in U S A FEDERAL SIGNAL CORPORATION Electrical Products Division 290A3806 MODEL 371 LIGHT VIBRATION MOUNT LOCKWASHER GROMMET 1 4 20 HEX NUT 1 290A3807 A B C D 2 Key A 6 25 158 8 mm B 9 32 7 1 mm...

Страница 15: ...ll installation instruc tions are followed A Unpacking After unpacking the light examine it for damage that may have occurred in transit If the equipment has been damaged do not attempt to install or...

Страница 16: ...worm on the motor shaft engages with the gear attached to the lamp shaft Apply a small amount of light high quality grease to the gear before re installing the motor cover plate h Attach the motor le...

Страница 17: ...N SHEET FOR mounting bracket kit Model 371brckt For commander lights Address all communications and shipments to FEDERAL SIGNAL CORPORATION Electrical Products Division 2645 Federal Signal Drive Unive...

Страница 18: ...tion for integrity and proper op eration Failure to follow all safety precautions and instructions may result in property damage serious injury or death to you or others I INSTALLATION This product is...

Страница 19: ...turned to Federal Signal for service inspection or repair must be accompanied by a Return Material Authorization This R M A can be obtained from a local Distributor or Manufacturer s Representative At...

Страница 20: ...290A3805 MODEL 371 LIGHT CONDUIT PLUG BRACKET BRACKET MOUNTING SCREWS MOUNTING SURFACE MOUNTING SCREWS USER SUPPLIED 1 2561546A Rev A 10 99 Made in U S A...

Отзывы: