1F 43 n
Select/cancel cursor display
n=0, canceled ; n=1, selected
0C
Clear display screen
18
Clear cursor line
1F 58 n
Brightness adjustment
1
≦
n
≦
4
1F 45 n
Blink display screen
0
≦
n
≦
255 (n*50msec) ON / (n*50msec) OFF
n= 0, blinking is canceled
n=255, display is turned off
1B 40
Initialize display
1B 74 n
Select character code table
0
≦
n
≦
5 ( Please refer
“Chapter 5”
)
1B 52 n
Select international character set
( Please refer
International Font Set Table
)
1F 72 n
Select/cancel reverse character
n=0, canceled ; n=1, selected
Command
Function Description
1F 01
Specify overwrite mode
1F 02
Specify vertical scroll mode
1F 03
Specify horizontal scroll mode
1B 57 n s (x1 y1 x2 y2)
Specify/cancel the window range
n=1,2,3,4 (four windows) ; s=0,1 (disable, enable)
1
≦
x1
≦
x2
≦
20 (column) ; 1
≦
y1
≦
y2
≦
2 (row)
1F 3A
Set starting/ending position of macro definition
1F 5E n m
Execute and quit macro
0
≦
(n,m)
≦
255
n: specifies the time interval for display of
characters in units of [n* 50msec]
m: specifies the interval of macro execution every
[m*50msec]
1F 40
Execute self-test
1F 54 h m
Display time :0
≦
h
≦
23 ; 0
≦
m
≦
59
1F 55
Display of time counter