FEASA LED ANALYSER
ICT VERSION
Specifications
Part Number(s)
Feasa 20-I
LED Analyser with 20 Fibers
Feasa 10-I
LED Analyser with 10 Fibers
Feasa 6-I
LED analyser with 6 Fibers
Feasa 5-I
LED Analyser with 5 Fibers
Feasa 3-I
LED Analyser with 3 Fibers
Feasa 2-I
LED Analyser with 2 Fibers
Feasa 20-IB
LED Analyser with 20 Fibers
Feasa 10-IB
LED Analyser with 10 Fibers
Feasa 6-IB
LED analyser with 6 Fibers
Feasa 5-IB
LED Analyser with 5 Fibers
Feasa 3-IB
LED Analyser with 3 Fibers
Feasa 2-IB
LED Analyser with 2 Fibers
Physical
-I, -IB
Dimensions 140mm x 29mm x 50mm (L x W x H) – 20I, 20IB
Dimensions 100mm x 29mm x 50mm (L x W x H) – 2I-10I, 2IB-10IB
Fiber Length 0.6m
Fiber Diameter 1.0mm
Fiber Core Diameter 0.5mm
Fiber Bend Radius 15mm
Plastic Fiber Temperature Range -40
0
C to +70
0
C
Number of Fibers 2, 3, 5, 6, 10, 20
Operating Temperature Range 0
0
C to +50
0
C
Electrical
Supply Voltage 5.0V +/- 0.5V
Supply Current 200 mA max
ICT Interface, Serial RS232 Interface
Output Data Format RGB, HSI, xy, uv, wavelength, cct
colour (Frequency):
1-100 Khz
Wavelength (Frequency):
1-100KHz
Saturation (Frequency):
1-100 Khz
x Chromaticity (Frequency):
1-100KHz
y Chromaticity (Frequency):
1-100KHz
Intensity (Frequency):
1-100 KHz
Optical
Red Peak Efficiency Wavelength 615 nm
Green Peak Efficiency Wavelength 540 nm
Blue Peak Efficiency Wavelength 465 nm
Total Operating Wavelength Range 450 nm to 650 nm
Accuracy
White X=± 0.01, Y = ± 0.01 @ x=0.33, y=0.33 using OH-3 Optical Head
Red (630nm) ± 4nm
Green (520nm) ± 2nm
Blue (450nm) ± 5nm
Yellow (590nm) ± 2nm
These accuracy's are based on the Led Analyser being calibrated at a point in time against known set values.