background image

INR-SI47-1246a

   

- 5 -

 

 

Table 1 shows the details of the data copying functions. 
 

Table 1    List of Data Copying Functions 

Display on 

LED Monitor 

Function Description 

read 

Read data 

Reads the function code data out of the inverter’s memory and stores it into the keypad 
memory. 
Also reads out inverter’s current running status information which can be checked by   
FRENIC Loader, such as information of I/O, system, alarm, and running status. 
Pressing the 

  key during a read operation (when

 

read

 

is blinking) immediately aborts 

the operation and displays

 

err

 (blinking). 

If this happens, the entire contents of the memory of the keypad will be completely cleared.

copy 

Write data 

Writes data stored in the keypad memory into the inverter’s memory. 
If you press the 

  key during a write operation (when

 

copy

 

is blinking), the write   

operation that is under way will be aborted and 

err

 

will appear (blinking).   

If this happens, the contents of the inverter’s memory (i.e., function code data) have been 
partly updated and remain partly old. Therefore, do not operate the inverter.   
Instead, perform initialization or rewrite the entire data. 
If this function does not work, refer to "

 If data copying does not work".

 

ueri 

Verify data 

Verifies (collates) the data stored in the keypad memory with that in the inverter's   
memory. 
If any mismatch is detected, the verify operation will be aborted, with the function code in   
disagreement displayed blinking. Pressing the 

  key again causes the verification to   

continue from the next function code. 

Pressing the 

  key during a verify operation (when

 

ueri

 

is blinking) immediately aborts 

the operation and displays

 

err

 

(blinking). 

err 

appears blinking also when the keypad does not contain any valid data.

 

proT 

Enable Data 

protection 

Enables the Data protection of data stored in the keypad’s memory. 
In this state, you cannot read any data stored in the inverter’s memory, but can write   
data into the memory and verify data in the memory. 
Upon pressing the 

  key the inverter immediately displays 

err

chec 

(*)

 

Read inverter 

running 

information 

Reads out inverter’s current running status information that can be checked by   
FRENIC Loader, such as information of I/O, system, alarm, and running status, excluding 

function code data. 
Use this command when the function code data saved in the PC should not be overwritten 
and it is necessary to keep the previous data. 
Pressing the 

  key during a read operation (

chec

 blinking) immediately aborts   

the operation and display

err

 (blinking).

 

 

 

To get out of the error state indicated by a blinking

 

err

 

 or

 

cper

 

, press the 

 key. 

When 

cper

 

is blinking, it indicates that the function code number does not match. But in this case the function   

codes which are consistent completely can continue copying after pressing 

 key. 

While 

cper

 is blinking, pressing 

  key changes display to flashing of

 

err

(*)  Ace(E2S) series of ROM version number less than 500 or Lift(LM2) series does not support “

chec

”.

 

 

 Data protection   

You can protect data saved in the keypad from unexpected modifications. Enabling the data protection that was disabled   
changes the display

 

read

 

  on the "Data Copying" function list to

 

proT

, and prohibits data reading from the inverter. 

To enable or disable the data protection, follow the steps below. 
(1) Select the "Data Copying"

 (

'cpy

 ) 

on the function selection menu in Programming mode. 

(2) When the 

'cpy

 

  is displayed, holding the 

  key down for at least 5 seconds alternates data protection status between 

  enabled or disabled. 

 

 

For switching the data protection status, be sure to hold the 

  key down for at least 5 seconds. Once the key is 

released within 5 seconds, press the 

  key to go back to the

 

' cpy

 

display and perform the keying operation 

again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

Dealers Industrial Equipment -- Visit 

https://DealersElectric.com

  or call (908) 688-1966 for all of your electric motor & VFD needs! 

Содержание TP-E1U

Страница 1: ...your product contact your Fuji Electric representative 2 Inverters with which the Remote Keypad Interfaces The remote keypad TP E1U interfaces with the following Fuji inverters Type of inverter Serie...

Страница 2: ...tion extension cable or commercially available LAN cable connect the remote keypad to the inverter insert one end of the cable into the RJ 45 connector on the remote keypad and the other end into that...

Страница 3: ...in the keypad with the one configured in the inverter The keypad serves as a temporary storage media In addition using Menu 7 allows you to store the running status information in the keypad detach th...

Страница 4: ...py 3 Press the key to proceed to the list of data copying functions e g read 4 Use the and keys to select the desired function then press the key to execute the selected function e g read will blink 5...

Страница 5: ...mory In this state you cannot read any data stored in the inverter s memory but can write data into the memory and verify data in the memory Upon pressing the key the inverter immediately displays err...

Страница 6: ...If cper is blinking any of the following problems has arisen The function codes stored in the keypad and ones registered in the inverter are not compatible with each other Either of the two may have...

Страница 7: ...check manage and monitor the function code data in real time to start or stop the inverter and to monitor the running or alarm status of the inverter Do not connect or disconnect the USB cable to the...

Страница 8: ...ast Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan Phone 81 3 5435 7058 Fax 81 3 5435 7420 URL http www fujielectric com Dealers Industrial Equipment Visit https DealersElectric com or cal...

Отзывы: