Document Number:
MAN
– FD220CV-C-1
Rev:
C
Revision Date:
01/10/2017
Page 7 of 16
©
2017 FDS Avionics Corp.
All Rights Reserved.
TECHNICAL SUPPORT
470-239-7421 or FDSAvionics.com
Power and Ground Wiring
20 AWG wire is recommended for Power and Ground applications.
This is a 28VDC monitor that requires 3 amps of power to operate. To operate properly this
monitor requires an input voltage of 24-29VDC.
The rated current of the equipment and associated voltage drop should be taken into
consideration when selecting wire gauge. The following example is based on an install with
a 28VDC power system and a total of 50 feet of wire between the circuit breaker, monitor
and ground.
Example: 22 AWG wire has 16.2 Ohms per 1000 feet, this equates to .81 Ohms for 50 feet.
3 Amps of current on .81 Ohms will drop 2.43 Volts.
Resistance of Wire Type M22759/16-**
(** = Gauge)
Gauge (AWG)
OHMS/1000’
24
26.20
22
16.20
20
9.88
16
4.81
12
2.02
10
1.26
8
.70
Also, use short heavy gauge wire and a clean tight connection for ground
.
It is the installer's responsibility to understand the product's requirements to install the
product in compliance with industry standards and safety.