3.0 OPERATOR CONTROLS
3.01 DYNA POWER controls
Figure 2
1. Main Circuit Bleaker— Switching to the ON position energizes the welding power source.
2. Fuse 8A
3. Fuse 2A
4. Fuse 2A
5. Inductance Control (GMAW)
6. Down Slope Voltage Control (Options)
7. Down Slope Wire Feed Speed Control (Options)
8. Wire Feed Speed Control
9. Voltage Control/ Amperage Control
10. Digital Meter
11. AC Power Indicator— Lights when in the ON position.
12. Warning Indicator— Activates under the following conditions:
•
Input voltage is too low/ too high
•
Thermal overload
13. Gas Switch— Switching to the ON position activate the gas.
14. Control Switch— 2T/4T.
15. Remote Control Switch— Switching to the ON position remote control start.