CAP-835
41
Fig. 41: Removing the cover from the intake filter
4.
Remove the cover from the intake filter
(Fig. 41-2).
5.
Remove the old filter element (Fig. 41-1).
6.
Insert the new filter element (Fig. 41-1).
7.
Replace the cover on the intake filter
(Fig. 41-2).
8.
Tighten the clamp on the intake filter
(Fig. 41-1).
7.6 Clean/replace scavenge line
1.
Close the shut-off valve on the outlet side
and secure it to prevent it from being opened
again.
2.
Open and remove the enclosure panels with
the special wrench.
3.
Use a drip pan to make sure that the leaking
oil is collected.
Fig. 42: Return line
4.
Unfasten the return line (Fig. 42-1) on the
air/oil separator (Fig. 42-2) and the
compressor airend (Fig. 42-3).
5.
Clean the return line (Fig. 42-1) and nozzle.
If necessary, replace them with original
spare parts (
Parts List).
6.
Place the nozzle and return line (Fig. 42-1)
back in position and tighten the screw
connections.
7.7 Measures after maintenance
has been performed
After completion of the maintenance work and
before switching the machine on, carry out the
following steps:
1.
Check all previously-loosened hose
connections and fittings to make sure they
are tight.
2.
Check whether all previously-removed
protective equipment and covers have been
replaced properly.
3.
Ensure that all tools, materials and other
equipment used have been removed from
the work area.
4.
Carefully open the compressed air outlet
shut-off valve.
5.
Clean the work area and remove any
substances such as liquids, processing
material or similar that may have escaped.
6.
Ensure that all safety equipment on the
machine functions perfectly.
7.
Document all work on the machine in the
maintenance log for warranty purposes.