Section 9 - System Programming
9–13
Question 07, L2
Remote Communications Ring Count
Default = 0
Selecting from the choices below, enter a digit in location L2.
Digit
REMOTE COMMUNICATIONS
RING COUNT
0
NONE (REMOTE COMMUNICATIONS
DISABLED)
1
1 RING
2
2 RINGS
3
3 RINGS
4
4 RINGS
5
5 RINGS
6
6 RINGS
7
7 RINGS
8
8 RINGS
9
9 RINGS
A
10 RINGS
B
11 RINGS
C
12 RINGS
D
13 RINGS
E
14 RINGS
F
15 RINGS
REMOTE COMMUNICATIONS RING COUNT - is the number of rings required for the
control panel to pick up and begin a remote communications session. Select a value that does
not interfere with normal operation of the panel. The default value is 12 rings.
NOTE: A value of 0 means that remote connect is disabled.
Question 07, L3
CS Test Time Interval
Default = 2
CS TEST TIME INTERVAL
CS TEST RESET BY
Digit
24 HOURS
WEEKLY
27 DAYS
60 DAYS
90 DAYS
TIME
EVENT
0
NONE (CS TEST DISABLED)
1
9
9
2
9
9
3
9
9
4
9
9
5
9
9
9
9
9
A
9
9
B
9
9
C
9
9
D
9
9
Содержание Omni-408A
Страница 14: ...OMNI 408A Installation and Setup Guide 2 6 ...
Страница 22: ...OMNI 408A Installation and Setup Guide 5 4 ...
Страница 28: ...OMNI 408A Installation and Setup Guide 6 6 ...
Страница 34: ...OMNI 408A Installation and Setup Guide 8 4 ...
Страница 76: ...OMNI 408A Installation and Setup Guide 12 2 ...
Страница 86: ...OMNI 408A Installation and Setup Guide B 4 ...
Страница 88: ...OMNI 408A Installation and Setup Guide C 2 ...
Страница 90: ...OMNI 408A Installation and Setup Guide D 2 ...
Страница 92: ...OMNI 408A Installation and Setup Guide E 2 ...
Страница 95: ......