23
Filling Barrel and Starting
The barrel, or freeze chamber, must be purged of air before filling with product. Failure to displace the air with
CO2 will result in poor drink quality.
1
Navigate to the SERVICE menu and then select the MAINTENANCE OPTIONS menu.
2
Highlight the desired barrel and then press the GAS PURGE button. Follow the prompts until
the process has completed.
3
Press the FILL BARREL button to begin filling with product. Follow the prompts until the
barrel is full and then press the END button. Use the vent valve to relieve pressure in the
barrel.
4
Once all barrels have been filled, return to the home menu.
5
Defrost the barrel(s) by pressing the green check mark button then selecting DEFROST.
This will defrost the highlighted barrel.
6
If you want to proceed to a freeze cycle right after the defrost cycle then press the green
check mark button again and select ON.
7
When the LCD display shows “ready” then the barrel is ready to be conditioned. Dispense
several drinks until lighter color product begins forming in the faceplate.
Vent valve used during
filling operation
Содержание 77 Series
Страница 1: ...772 773 774 24 2396 0001 Rev C 07 30 2013...
Страница 38: ...38 772 Mounting Dimensions 773 Mounting Dimensions...
Страница 40: ...40 WIRING SCHEMATIC DIAGRAM...
Страница 41: ...41...
Страница 42: ...42 REFRIGERATION SCHEMATIC DIAGRAM...