INSTALLATION & OPERATION ADDENDUM
77X SERIES–FC
6
5
Place a large container under the dispensing valve and drain the barrel. Activating the beater motor
will facilitate draining the barrel when near empty. Deactivate the solution solenoid when the
syrup lines have been purged. Continue purging the barrel and then deactivate the gas solenoid
when the barrel has been emptied.
6
Place the syrup BIB connector with adapter in the sanitizing solution.
7
Activate the solution solenoid and begin filling the barrel with sanitizing solution. Pull the relief
valve as necessary to vent the pressure allowing the fill process to continue. Deactivate the solution
solenoid when the barrel is 3/4 full.
8
Activate the beater motor and agitate for three minutes.
9
While the beater motor is agitating, dispense some sanitizing solution from the relief valve to ensure
they are both sanitized as well.
10 Remove the BIB connector from the sanitizing solution and reconnect to the syrup supply.
11 Activate the solution solenoid.
12
Place a large container under the dispensing valve and drain the barrel. Activating the beater
motor will facilitate draining the barrel. Deactivate the solution solenoid when the syrup lines have
been primed with syrup. Continue purging the barrel and then deactivate the gas solenoid when
the barrel has been emptied.
13
Activate the solution solenoid and beater motor again. When the barrel is 1/2 full, deactivate the
solution solenoid to stop the fill process.
14
Activate the gas solenoid and drain the barrel. This step removes the remaining sanitizing solution
left in the barrel. Deactivate the gas solenoid and beater motor when the barrel is empty.
15
Navigate to the MAINTENANCE MENU and start the FILL BARREL process. Follow the prompts until
the barrel is full.
16 If any sanitizer off-taste remains, drain the barrel again and refill.
1
On the home screen press the up or down arrow until the barrel to be sanitized is highlighted.
Press the green button and then select OFF. Press the green button again and select DEFROST.
2
While the barrel is defrosting, remove the drip tray (if not connected to drain plumbing), splash
plate, and the cover located behind the splash plate.
3
Take an empty BIB and cut off the connector to make an adapter. Alternatively, if the product is
supplied through a premixed product storage container, clean and sanitize that container per
local health code, and then fill the sanitizing solution into the container. Attach the BIB connector
(adapter) to the connector on the product input line and then allow the solution to be pumped
into the unit.
4
Once the barrel has defrosted, navigate to the MANUAL ON/OFF menu located in the SERVICE
MENU section and activate both the gas and solution solenoids for the barrel to be sanitized.