INSTALLATION & OPERATION ADDENDUM

77X SERIES–FC

6

5

Place a large container under the dispensing valve and drain the barrel.  Activating the beater motor 
will facilitate draining the barrel when near empty.  Deactivate the solution solenoid when the 
syrup lines have been purged.  Continue purging the barrel and then deactivate the gas solenoid 
when the barrel has been emptied.

6

Place the syrup BIB connector with adapter in the sanitizing solution.

7

Activate the solution solenoid and begin filling the barrel with sanitizing solution.  Pull the relief 

valve as necessary to vent the pressure allowing the fill process to continue.  Deactivate the solution 
solenoid when the barrel is 3/4 full.

8

Activate the beater motor and agitate for three minutes.

9

While the beater motor is agitating, dispense some sanitizing solution from the relief valve to ensure 
they are both sanitized as well.

10 Remove the BIB connector from the sanitizing solution and reconnect to the syrup supply.

11 Activate the solution solenoid.

12

Place a large container under the dispensing valve and drain the barrel.  Activating the beater 
motor will facilitate draining the barrel.  Deactivate the solution solenoid when the syrup lines have 
been primed with syrup.  Continue purging the barrel and then deactivate the gas solenoid when 
the barrel has been emptied.

13

Activate the solution solenoid and beater motor again.  When the barrel is 1/2 full, deactivate the 

solution solenoid to stop the fill process.

14

Activate the gas solenoid and drain the barrel.  This step removes the remaining sanitizing solution 

left in the barrel.  Deactivate the gas solenoid and beater motor when the barrel is empty.

15

Navigate to the MAINTENANCE MENU and start the FILL BARREL process.  Follow the prompts until 
the barrel is full.

16 If any sanitizer off-taste remains, drain the barrel again and refill.

1

On the home screen press the up or down arrow until the barrel to be sanitized is highlighted.  

Press the green button and then select OFF.  Press the green button again and select DEFROST.

2

While the barrel is defrosting, remove the drip tray (if not connected to drain plumbing), splash 
plate, and the cover located behind the splash plate.

3

Take an empty BIB and cut off the connector to make an adapter. Alternatively, if the product is 
supplied through a premixed product storage container, clean and sanitize that container per 
local health code, and then fill the sanitizing solution into the container. Attach the BIB connector 
(adapter) to the connector on the product input line and then allow the solution to be pumped 
into the unit. 

4

Once the barrel has defrosted, navigate to the MANUAL ON/OFF menu located in the SERVICE 
MENU section and activate both the gas and solution solenoids for the barrel to be sanitized.

Содержание 77 FC Series

Страница 1: ...77X SERIES INSTALLATION OPERATION ADDENDUM FOR LOW TEMPERATURE FROZEN COCKTAIL 24 77XA 0003_03...

Страница 2: ...ardless of the theory of liability arising out of or in any manner related to FBD parts equipment or any delay with respect to its delivery The information contained in this document is subject to cha...

Страница 3: ...uirements INSTALLATION Dispenser Mounting The FC unit is not designed to be sealed to a countertop surface or floor use the information in this section instead of Section 4 2 in the Installation and O...

Страница 4: ...n Manual for details Additionally FC syrup equipment must be rated for use with direct food contact as well as alcohol contact with an ABV of less than 14 LEAK CHECK AND PRIME Leak Check and Prime FC...

Страница 5: ...nlikestandardFBDdispensers DisregardtherequirementinSection 8 1 of the Installation and Operation Manual to disconnect the water lines Sanitizing Use the information in the following table instead of...

Страница 6: ...as solenoid when the barrel has been emptied 13 Activate the solution solenoid and beater motor again When the barrel is 1 2 full deactivate the solution solenoid to stop the fill process 14 Activate...

Страница 7: ...Barrel BRL 4 Product Source Inline Pressure Transducer Expansion Tank Product Barrel Liquid Flow Gas Flow Check Valve Check Valve Solenoid S Gas Solenoid Check Valve Gas Solenoid Check Valve Pressure...

Страница 8: ...SS VALVE REFRIGERATION DIAGRAM INSULATION REQUIRED FILTER DRIER TEMPERATURE SENSOR T P PRESSURE SENSOR EXPANSION VALVE 03 03 BARREL EVAPORATOR 02 BARREL EVAPORATOR 01 BARREL EVAPORATOR EXPANSION VALVE...

Страница 9: ...l of this product must comply with local regulations Dispenser is not to be disposed of with household waste Contact the retailer where this dispenser was purchased or recycle by locating an authorize...

Отзывы: