Fazzini F-18 Battery Скачать руководство пользователя страница 5

 

Suction Pump 

 

F-18/F-36/F-20/F-40 

S e r v i c e   M a n u a l

     

 

 

Doc : Service Manual - F-18-36-20-40 Rev. 1 del 20 SEP 2005 
Page 5 di 12 

 

HOW TO CLEAN THE APPLIANCE

DISCONNECT THE APPLIANCE FROM THE ELECTRIC SUPPLY NETWORK AND THEN CLEAN IT WITH A SOFT CLOTH 
WETTED WITH NON ABRASIVE DETERGENTS 

 
 

PERIODIC MAINTENANCE CHECK 

ASPIRATOR WAS DESIGNED TO KEEP MAINTENANCE TO A MINIMUM. NEVERTHELESS IT IS NECESSARY TO CARRY OUT 
A DAILY CHECK BEFORE USING THE APPLIANCE. 
 
BEFORE CARRYING OUT ANY CHECK DUE TO MALFUNCTIONING OR ANOMALIES, CALL THE FAZZINI S.R.L. TECHNICAL 
SERVICE OR PERSONNEL QUALIFIED BY FAZZINI S.R.L. 
 
FAZZINI S.R.L. DOES NOT OFFER ANY WARRANTY ON APPLIANCE THAT UPON INSPECTION BY THE TECHNICAL SERVICE 
SHOWS SIGNS OF  TAMPERING. 
THE OPERATOR MUST EXCLUSIVELY REPLACE THE SUPPLIED ACCESSORIES IF NECESSARY IN LINE WITH THE 
APPLIANCE’S USE INTENSITY 
ASPIRATION TUBES SHOULD BE STERILIZED AFTER EACH USE. 
IN CASE OF REPAIR, THE USER SHOULD CALL FAZZINI S.R.L. 
TRANSPORTATION COSTS MUST ALWAYS BE AGREED WITH FAZZINI S.R.L.  BEFORE SHIPPING FAILED PIECES. 
SHOULD ANY FLUID LEAK IN THE APPLIANCE, CALL THE TECHNICAL SERVICE OF FAZZINI S.R.L. FOR MAINTENANCE. 
DO NOT OPEN THE UNIT. 

 

STORAGE 

THE ASPIRATOR MUST BE STORED IN A DRY LOCATION, PROTECTED FROM ATMOSPHERIC AGENTS 
STORAGE TEMPERATURE: BETWEEN -10° AND + 55° 
RELATIVE HUMIDITY BETWEEN 20 AND 80% 

 

DISPOSAL 

WITH REFERENCE TO THE DISPOSAL OF THE APPLIANCE, ITS ACCESSORIES AND ITS SINGLE USE DISPOSABLE PARTS, 
PLEASE SEE CURRENT WASTE DISPOSAL REGULATIONS 

 

 

 
 

 

 
 

 

 
 

 

 

 
 

 

 
 

 

 
 

 

 

 
 

 

 
 

 

 
 
 

Содержание F-18 Battery

Страница 1: ...n Pump F 18 F 36 F 20 F 40 S e r v i c e M a n u a l Doc Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 1 di 12 NOTE This manual is related to the following Equipment Suction Pump F 18 F 36 F 20 F 40 ...

Страница 2: ...bout the equipment spare parts and the information supplied CAUTIONS BEFORE STARTING TO INSPECT THE DEVICE MAKE SURE IT IS NOT CONNECTED TO THE ELECTRIC POWER SUPPLY NETWORK DO NOT USE THE APPLIANCE IN THE PRESENCE OF INFLAMMABLE AND OR EXPLOSIVE LIQUIDS GASES OR MIXTURES DO NOT LEAVE THE APPLIANCE EXPOSED TO ATMOSPHERIC AGENTS OR HEAT SOURCES USING THE APPLIANCE UNDER DIFFERENT CONDITIONS THAN TH...

Страница 3: ...XPOSED TO ATMOSPHERIC AGENTS OR HEAT SOURCES DO NOT LET CHILDREN OR INCAPABLE PERSONS USE THE APPLIANCE WITHOUT THE NECESSARY SUPERVISION BEFORE STARTING TO CLEAN THE DEVICE MAKE SURE IT IS NOT CONNECTED TO THE ELECTRIC POWER SUPPLY NETWORK DO NOT USE THE APPLIANCE FOR AIMS OTHER THAN THOSE FORESEEN BY THE MANUFACTURER USING THE APPLIANCE UNDER DIFFERENT CONDITIONS THAN THOSE SPECIFIED IN THIS HAN...

Страница 4: ...W VALVE WILL STOP ASPIRATION 11 IMMEDIATELY SWITCH OFF THE APPLIANCE BY SETTING THE ON OFF 7 SWITCH ON THE OFF POSITION THE MANUFACTURER ASSEMBLER INSTALLER OR IMPORTER ARE HELD LIABLE FOR THE SAFETY PERFORMANCE AND RELIABILITY OF THE APPLIANCE ONLY IF THE ELECTRIC SYSTEM TO WHICH THE APPLIANCE IS CONNECTED COMPLIES WITH L D 46 90 ACCESSORIES INCLUDED CODE N 05 0001 05 00552 05 0010 05 0015 DESCRI...

Страница 5: ... ON APPLIANCE THAT UPON INSPECTION BY THE TECHNICAL SERVICE SHOWS SIGNS OF TAMPERING THE OPERATOR MUST EXCLUSIVELY REPLACE THE SUPPLIED ACCESSORIES IF NECESSARY IN LINE WITH THE APPLIANCE S USE INTENSITY ASPIRATION TUBES SHOULD BE STERILIZED AFTER EACH USE IN CASE OF REPAIR THE USER SHOULD CALL FAZZINI S R L TRANSPORTATION COSTS MUST ALWAYS BE AGREED WITH FAZZINI S R L BEFORE SHIPPING FAILED PIECE...

Страница 6: ... Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 6 di 12 Legenda F 18 F 36 1 Filter 2 Vacuum drive 3 Jar drive to the filter 4 Silicone tube to the patient 5 Jar drive to the patient 6 Suction catheter CH 14 7 Main switch 8 Vacuum regulator 9 Vacuum gauge ...

Страница 7: ... F 36 F 20 F 40 S e r v i c e M a n u a l Doc Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 7 di 12 General assembly F 18 F 36 SP 32 05 Single head 230V motor for F 18 SP 32 01 Double head 230V motor for F 36 ...

Страница 8: ... Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 8 di 12 Legenda F 20 F 40 1 Filter 2 Vacuum drive 3 Jar drive to the filter 4 Silicone tube to the patient 5 Jar drive to the patient 6 Suction catheter CH 14 7 Main switch 8 Vacuum regulator 9 Vacuum gauge ...

Страница 9: ... F 36 F 20 F 40 S e r v i c e M a n u a l Doc Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 9 di 12 General assembly F 20 F 40 SP 32 05 Single head 230V motor for F 20 SP 32 01 Double head 230V motor for F 40 ...

Страница 10: ... M a n u a l Doc Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 10 di 12 Functional layout 4 2 3 1 Feeding wire Brown Feeding wire Blue Feeding wire Brown Feeding wire Blue 4 3 1 IEC Power inlets 2 M IEC double pole switch Feeding 50 60 Hz ...

Страница 11: ...0 S e r v i c e M a n u a l Doc Service Manual F 18 36 20 40 Rev 1 del 20 SEP 2005 Page 11 di 12 Pneumatic circuit 7 6 5 4 3 2 1 1 Catheter to the patient 2 Suction regulator 3 Jar 4 Non rebeathing valve 5 Filter 6 Pump Motor 7 Vent ...

Страница 12: ...er switch is damaged In ON position check the presence of the light if no light is detected replace with a spare switch 1 Equipment will not turn on e Internal wiring connection are not completed Open the equipment and verify internal electrical wiring see functional layout Situation Possible Cause Solution a Vacuum regulator do not work properly Turn the manifold SP 21 b Internal tubing are not p...

Отзывы: