9.6 Malfunctions during operation
Fault
Possible cause
Remedy
The machines
vibrates forward
with a strongly
reduced speed
Air in the hydraulic system of the steering
rod
Release pressure from the steering rod
The oil level in the exciter shaft housing
is too high
Check the oil level in the exciter shaft
housing
Protective equipment:
n
Protective gloves
1.
Park the machine in secured condition
„Parking the machine in secured condition“ on page 55
.
2.
Press the handle forward against the end stop and hold it in
this position.
3.
Carefully loosen the filler screw (1).
ð
The air makes a slight hissing sound when escaping.
4.
Wait until all air has escaped and then tighten the filler screw.
Release pressure from the steering
rod
Fig. 116
Troubleshooting – Malfunctions during operation
DRP40DX
105
Содержание DYNAPAC DRP40DX
Страница 2: ...2 ...
Страница 6: ...Table of contents DRP40DX 6 ...
Страница 7: ...1 Introduction Introduction DRP40DX 7 ...
Страница 11: ...2 Technical data Technical data DRP40DX 11 ...
Страница 15: ...3 Concerning your safety Concerning your safety DRP40DX 15 ...
Страница 40: ...Concerning your safety Signage DRP40DX 40 ...
Страница 41: ...4 Indicators and control elements Indicators and control elements DRP40DX 41 ...
Страница 43: ...5 Checks prior to start up Checks prior to start up DRP40DX 43 ...
Страница 49: ...6 Operation Operation DRP40DX 49 ...
Страница 56: ...Operation Parking the machine in secured condition DRP40DX 56 ...
Страница 57: ...7 Loading transporting the machine Loading transporting the machine DRP40DX 57 ...
Страница 61: ...8 Maintenance Maintenance DRP40DX 61 ...
Страница 96: ...6 Check the oil levels 7 Clean the machine thoroughly Maintenance As required DRP40DX 96 ...
Страница 97: ...9 Troubleshooting Troubleshooting DRP40DX 97 ...
Страница 106: ...Troubleshooting Malfunctions during operation DRP40DX 106 ...
Страница 107: ...10 Disposal Disposal DRP40DX 107 ...
Страница 109: ......
Страница 110: ......