10.4 Engine malfunctions
Fault
Possible cause
Remedy
Engine does
not start
Fuel tank empty
Refuel, bleed the fuel system
Fuel filter gets clogged in
winter due to paraffin separa-
tion
Replace the fuel filter; use
winter fuel.
Fuel lines leaking
Check all line connections for
leaks, tighten the screw con-
nections and bleed the fuel
system
Battery is not charged or not
connected
Tighten the connection termi-
nals on the battery, check the
line connections
Emergency stop switch is
locked in place
Unlock the emergency stop
switch
Starter defective
Have examined by a spe-
cialist.
Engine starts
with difficulty
or runs irregu-
larly at low
power
Battery power is too low, con-
nection terminals are loose
and oxidised, causing the
starter to rotate slowly
Check the battery charge,
clean and tighten the connec-
tion terminals and coat them
with acid-free grease
Fuel supply is too low, fuel
filter is clogged in winter due
to paraffin separation
Replace the fuel filter
Check all line connections for
leaks, tighten the screw con-
nections and bleed the fuel
system
Use winter fuel in winter
Engine oil with wrong SAE
viscosity class
Changing the engine oil
Air filter contaminated
Clean, replace if necessary
Water in the fuel system
Checking and clean the water
separator, if necessary
Injection nozzle or injection
pump is defective
Have examined by a spe-
cialist.
Troubleshooting – Engine malfunctions
BW 100 ADM-5
207
Содержание BOMAG BW 100 ADM-5
Страница 9: ...1 Introduction Introduction BW 100 ADM 5 9 ...
Страница 13: ...2 Technical data Technical data BW 100 ADM 5 13 ...
Страница 18: ...Technical data Noise and vibration data BW 100 ADM 5 18 ...
Страница 19: ...3 Concerning your safety Concerning your safety BW 100 ADM 5 19 ...
Страница 65: ...4 Indicators and control elements Indicators and control elements BW 100 ADM 5 65 ...
Страница 82: ...Indicators and control elements Outside of machine BW 100 ADM 5 82 ...
Страница 83: ...5 Checks prior to start up Checks prior to start up BW 100 ADM 5 83 ...
Страница 97: ...6 Operation Operation BW 100 ADM 5 97 ...
Страница 128: ...Operation Emergency procedures BW 100 ADM 5 128 ...
Страница 129: ...7 Loading transporting the machine Loading transporting the machine BW 100 ADM 5 129 ...
Страница 139: ...8 Maintenance Maintenance BW 100 ADM 5 139 ...
Страница 194: ...Maintenance As required BW 100 ADM 5 194 ...
Страница 195: ...9 Setting up refitting Setting up refitting BW 100 ADM 5 195 ...
Страница 200: ...Setting up refitting Edge cutter mounting and removing tools BW 100 ADM 5 200 ...
Страница 201: ...10 Troubleshooting Troubleshooting BW 100 ADM 5 201 ...
Страница 206: ...Fuse Amperage Designation F00 80 A Main fuse Troubleshooting Fuse assignment BW 100 ADM 5 206 ...
Страница 212: ...Troubleshooting Trouble shooting ECONOMIZER BW 100 ADM 5 212 ...
Страница 213: ...11 Disposal Disposal BW 100 ADM 5 213 ...
Страница 215: ......
Страница 216: ......