WARNING!
Danger of injury!
Do not let the starter handle hit back, but guide it back
slowly.
Remove the fixing of the coil and run the starter handle
slowly back to initial position
Test function and light movement of the recoil starter by
pulling the starter handle.
NOTICE!
Do not mix up the fastening screws for the recoil
starter by mistake!
clamp (3) to the recoil starter.
Attach the screw M6x16 (6) with washer (5) and bracket for
engine guard plate to the recoil starter.
Attach the screw M6x8 (4) to the recoil starter.
Tighten screws (1), (4) and (6).
6.8.6 Oil change in tamper foot
WARNING!
Danger of burning on hot components!
Wear your personal protective outfit (protective gloves,
protective clothing).
Fig. 76
Fig. 77
Mount the recoil starter to the
engine housing:
Maintenance
BT 60 / BT 65
67