9.7 Trouble shooting ECONOMIZER
Malfunction
Possible cause
Remedy
LED (a) flashing
Switching on: The LED (a) flashes for
approx 1 - 2 seconds after the vibration
has bee switched on.
Vibration frequency too low
Acceleration sensor is not connected
Check the connection of the acceleration
sensor
Cable breakage
Inform our service department
LED (a) lights
No vibration detected
Starting the engine
Check the connection of the acceleration
sensor
The displayed
measuring values
are not plausible
The acceleration sensor is not fastened
correctly
Shut down the engine and check the fas-
tening screws for the acceleration trans-
ducer
Weak spots in the road subbase
In unfavourable cases an excessively
varying material composition or moisture
can influence the measuring results.
On considerably dry or excessively moist
material lower measuring values will be
displayed.
Fig. 82: Economizer display
Troubleshooting – Trouble shooting ECONOMIZER