Remove the filter cover (3)
Unscrew the knurled nut (2) and pull out the air filter (1).
NOTICE!
The clean air side must be kept clean of dirt and for-
eign particles.
Do not blow the inside of the filter housing out with
compressed air.
Wipe the inside of the filter housing only with a clean cloth.
Clean the cover thoroughly.
WARNING!
Danger of injury!
Always wear protective clothes (goggles, gloves) when
working with compressed air.
Blow the air filter
Fig. 46 out from inside to outside with
dry compressed air (max. 5 bar (73 psi)).
Check the air filter for damage, replace if necessary.
Fig. 45 into the housing and fasten it
with the knurled nut (2).
Install the filter cover (3), ensure correct fit of cover and seal.