![Fayat Group DYNAPAC CC425 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/fayat-group/dynapac-cc425/dynapac-cc425_instruction-manual_546903075.webp)
67
Maintenance
Coolant System
Check that all hoses/hose connectors are intact
and tight. Fill with coolant as specified in the
lubricants specification.
Change the coolant every year. Failure to cool the
engine properly can result in engine failure or
severely reduce engine life.
Figure 7-9: Coolant Level Gauge
Water Tank
Unscrew the tank cap and fill with clean water. Do
not remove the strainer. See technical
specifications for the tank volume.
N o t e
A small amount of environment-
friendly antifreeze is added.
Figure 7-10: Water Tank
A
Tank cap
A
Coolant level gauge
Personal injury can occur when removing
the radiator cap. Steam or fluid escaping
from the radiator can burn. Inhibitor
contains alkali. Avoid contact with skin
and eyes. Wear protective gloves and
eye glasses.
Always shut off the engine and allow it to
cool down before removing the radiator
cap. Remove the radiator cap slowly to
relieve pressure. Avoid contact with
steam or escaping fluid.
Fixed Scrapers
Make sure that the scrapers are undamaged.
Adjust the scrapers so that they are 1-2 mm from
the drum. For special asphalt compounds, it may
be better if the scraper blades lie lightly against
the drums.
Asphalt remnants can accumulate on the scraper
and affect the contact force. Clean as required.
1. Loosen the screws to adjust the contact
pressure of the scraper blade against the
drum.
2. Lock this setting by tightening the lock nut
against the mounting plate.
3. Adjust the contact surface on both scraper
attachments.
!
!
A
Содержание DYNAPAC CC425