![Fayat Group DYNAPAC CC425 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/fayat-group/dynapac-cc425/dynapac-cc425_instruction-manual_546903027.webp)
19
Special Instructions
Jump Starting
Do not connect the negative cable to the negative
terminal on the dead battery. A spark can ignite
the oxy-hydrogen gas formed around the
battery.
Check the battery used for jump starting has
the same voltage as the dead battery.
1. Turn off the ignition and all power consuming
equipment.
2. Switch off the engine on the roller which is
providing jump start power.
3. Connect the jump start battery's positive
terminal (A) to the flat battery's positive
terminal (B).
4. Connect the jump start battery's negative
terminal (C) to, for example, a bolt (D) or the
lifting eye on the roller with the flat battery.
5. Start the engine on the power providing roller.
Let it run for a while. Now try to start the other
roller.
6. Disconnect the cables in the reverse order.
Figure 3-1: Jump Starting
A
Battery's positive terminal one
B
Battery's positive terminal two
C
Battery's negative terminal three
D
Battery's negative terminal four
!
!
Fig. Ignition key & battery disconnector
1. Ignition key
2. Battery disconnector
Ignition key & Battery Dis-connector key
removal In transit
While transporting the machine on the trailer or
container or in long-term parking always ensure
that
1. Ignition key should be removed from the
Ignition switch
2. Battery dis-connector key should be
removed
.
This will avoid static parasitic current
consumption & saves the battery life & potential
battery drain issue