VI. Turning off
1. To switch of the device, close the canister valve (B).
V. Start up and use
1.
The column (3) may not be lowered for startup!
2. Open the canister valve (B)
3. Press the initiator until a clicking sound can be heard. Now press
the adjustment button in the adjustment of a small flame symbol until
it catches. After successful ignition, keep pressing the adjustment
button for an additional 10 seconds, in order to activate the safety
pilot.
If in exceptional cases, the burner has not ignited after 5 to 7 seconds,
repeat the process after a waiting period of approx. 2 minutes.
Note:
It is possible to ignite the device using other primers
(matches, fire sticks) which are ignited through the
burner base openings Ø18.5mm.
F
G
Battery size: AA 1.5V
If the flame on the burner can no longer
be ignited with the initiator, the battery
must be replaced.
To open, turn the cap of the initiator to the left
(counter-clockwise). Replace the empty battery
with a fresh battery and screw the cap of the
initiator on by turning clockwise.
Do not dispose of the empty battery in the
household waste, but rather deliver it to a battery
collection center.
23
GB
Assembly instructions COSY RATTAN • 05-01-2011
IV. RATTAN use
CAUTION: According to German safety regulations BGV D34 (VBG 21), a DIN
30 693 approved hose rupture guard and a safety pressure regulator with
an excess pressure valve must be fitted when using the heater in a RATTAN
setting (e.g. at fetes). A hose rupture guard and a safety pressure regulator
are not supplied. These can be acquired as accessories in specialist shops.
AS IT IS SUPPLIED TO THE CUSTOMER, THE PATIO HEATER IS ONLY
INTENTED FOR PRIVATE USE.
600551566_300551566_RATTAN_FAVEX_MANUAL_FR_DE_GB_NL_ES_IT_050111.indd 23