FA-07

) is a multifunctional apparatus used for the sport of fencing.

1.1

Included and optional accessories

Accessories included with the 

FA-07

:

Carrying case;

Infrared and cable-operated remote control;

Power supply 90÷264Vac/12Vdc 2.5A, conforms to UL 60601-1 standards;

2 telephone cables 15m and 2.5m in length, with RJ-14 (6P4C) jacks for connection via the SERIAL DATA ports ;

2 telephone cables 10m and 1.3m in length, with RJ-10 (4P4C) jacks for connection to the remote control. The short cable
is more convenient for recharging the battery.

Optional accessories:

Art.944 - Table Stand 96cm high for 

FA-07

;

Art.945 - Pair of 360° Tower-Lights for 

FA-07

;

Art.948 - Carrying case for Table Stand 96cm and Tower-Lights;

Art.828 - Rechargeable Battery 12V/7Ah with connectors;

Art.829 - Battery Recharger (for Art.828 battery);

Art.856 - Power cable with clamps for connecting to a car battery (length: 3.5m);

Art.880 - Doubler for SERIAL DATA.

1.2

Technical Data

Size and weight of 

FA-07

 (scoreboard): 55 x 35 x 9.5cm, 4.2kg

Size and weight of infrared remote control: 14.3 x 5 x 2.3cm, 0.19kg

Size and weight of carrying case: 60 x 40 x 13.5cm, 2.8kg

Total weight of 

FA-07

 with carrying case and included accessories: 8.1kg

Operating temperature: 0..45°C

Storage temperature: -20..+85°C

Relative humidity: 10..90%

Level of protection: IP32

Remote control battery: 3.6V 600mA, Lithium-ion

Battery recharge time: 7hrs max

1.3

Warranty

The warranty is good for 2 years from the date indicated on the purchase agreement and includes free repair of all defects
found in materials or in construction; the warranty does not cover delivery or transportation costs. The portable power supply
(Art.954) provided with the 

FA-07, 

and the optional battery (Art.828), are not covered by the warranty.

1.4

Power supply

Power supply voltage: 12Vdc (10.6-14.5Vdc).

Consumption: 0.5A typical,

0.85A max, without the Tower-Lights,
2.3A max, with both TOWER-LIGHTS connected and switched on.

1.4.1 Safety warning

WARNING: Supply power to the 

FA-07

 exclusively by means of the power supply unit provided (Art.954) to ensure

that safety isolation requirements are met; otherwise supply power by means of a 12Vdc battery.

1.4.2 Battery power supply

We recommend using a lead-acid 12V battery. The battery listed in the catalogue (Art.828) enables uninterrupted use of the

FA-07

 for 10-12 hours, while a 70Ah car battery lasts 120 hours. On the 

FA-07

 graphic display panel the power supply voltage

is indicated and relates to the remaining life of the battery.  When the battery’s  voltage is 12.0V, only about 5-10% of  its
capacity is available. We recommend recharging the battery after each use or, in any case, if the voltage is <12.5V  . We also
recommend recharging the battery at least every 6 months when not used for long periods, mainly due to the fact that if left to
run down, it will deteriorate and lose its power completely. 
The battery’s positive pole must be connected to the number 2 contact of the power supply connector, otherwise the 

FA-07

will not switch on. If the  

FA-07

  does not switch on after connecting it to a car battery, try inverting the connections to the

clamps.

940-M06-EN FA-07 Manual

Page 3/ 16

FAVERO ELECTRONICS SRL

Содержание FA-07

Страница 1: ...keys 6 4 5 Battery charging 8 4 5 1 Low battery indication 8 5 PROGRAMMING TEST MENUS 9 5 1 Introduction 9 5 2 Description of programming steps 9 5 3 Description of tests 9 6 OPERATION VIA LAN 11 6 1 Preliminary information 11 6 2 Software for the central system for managing competitions 11 6 3 LAN connections 11 6 4 IP addresses and checking connection status 12 6 5 Matches managed via LAN 12 6 5...

Страница 2: ...0 01 FA 07 Scoreboard without accessories Art 952 FA 07 remote control Art 858 2 5m Cable for Serial Data Art 859 15m Cable for Serial Data Art 954 Power Supply 90 264V 12Vdc 2 5A Medical Art 828 Rechargeable battery 12Vdc 7Ah Art 829 Battery charger for Art 828 battery Art 880 Doubler for SERIAL DATA Art 856 Power cord with clamps for connecting to a car battery Art 948 Carrying case for Tower Li...

Страница 3: ... purchase agreement and includes free repair of all defects found in materials or in construction the warranty does not cover delivery or transportation costs The portable power supply Art 954 provided with the FA 07 and the optional battery Art 828 are not covered by the warranty 1 4 Power supply Power supply voltage 12Vdc 10 6 14 5Vdc Consumption 0 5A typical 0 85A max without the Tower Lights 2...

Страница 4: ...s follows 1 Selected weapon and version or else temporary notification of faults or other information 2 Rearmament time 1 3 5 Man Rearmament can take place automatically after 1 3 or 5 seconds or else manually 3 Start time minutes of chronometer 4 Nationality of fencers 5 Names of fencers as with nationalities the names of the fencers appear only when the FA 07 receives the information from the ce...

Страница 5: ...See chapter 7 1 Insert the RESERVE fencer on the left side in team competitions On the FA 07 display panel the name of the fencer will be replaced by the words RESERVE The key is active when the competitions are managed via a LAN connection after confirming the match by the Alt 1 BEGIN keys Same as with F1 key but for the right side Increase the number of medical interventions for the correspondin...

Страница 6: ...p P 03 select Block Remote Control YES see chapter 5 2 Remember to unblock this function at the end of the competition otherwise future users who are not familiar with or who do not remember this function might assume that the remote control is not working properly 4 3 Remote control indications There are 2 red lights on the remote control see Fig 5 Transmission light signals each transmission If ...

Страница 7: ...f matches Fx not used Alt 1 WEAPONS effectuate the change of weapon in the same way that the corresponding key on the FA 07 keyboard does Fencers_swap inverts all the visual displays regarding the two fencers This is used when fencers change positions Alt 1 1sec decrease the value of the chronometer by 1 second to allow for corrections to be made During the last 10 seconds time decrease is display...

Страница 8: ...ed A totally depleted battery is recharged in circa 7 hours while a charged battery lasts circa 300 hours of competition time We suggest charging the battery at least once a year if the remote control is not used 4 5 1 Low battery indication If the remote control battery is low the FA 07 s graphic display panel will switch off for a brief moment and the message Remote Control Battery Low will appe...

Страница 9: ...meter P 04 IP 000 000 000 000 254 254 254 254 When a LAN connection is used each apparatus must have a different IP address We suggest using a number from 192 168 000 020 to 192 168 000 254 if not already in use by other devices Use the key to select the number you wish to modify and the keys and to modify it P 05 Port number 01025 65535 This number is used for connection to the LAN We suggest tha...

Страница 10: ...all the contact combinations that take place between fencers It can also be useful to the user for distinguishing if the indications of faults are due to failure of the internal circuits or to defects in the external connections The display panel see Fig 12 shows 12 values in the three columns to the left and in the far right column the corresponding values Higher H Middle M Lower L and Deviation ...

Страница 11: ... Alt 1 PREVIOUS for the data from the previously concluded match in order to correct any possible errors The central system decides whether to accept the request or not For more information on management of the match via LAN see chapter 6 5 6 2 Software for the central system for managing competitions Communication between the central system and the various FA 07 apparatuses connected to the LAN t...

Страница 12: ...alue etc for managing team competitions where the matches which immediately follow continue with the previous scores and the match number is automatically determined by the central system The reception of all data is also necessary when a previously interrupted match is recalled see chapter 6 5 4 Information regarding the new match may include the time the match is scheduled to begin if so the tim...

Страница 13: ...em has been informed of the match end and the MATCH Running light has been switched off a new match can be requested as described in chapter 6 5 1 6 5 4 Correcting a previously sent match Via the Alt 1 PREVIOUS keys of the remote control the referee can ask the central system for the data pertaining to the previously concluded match in order to make eventual corrections The central system will dec...

Страница 14: ...Ethernet port This port allows the FA 07 to be connected A directly to a PC for updating software as described in chapter 8 B to a LAN in order to manage the entire competition via the central system as described in chapter 6 The Ethernet port has a 1500V isolation to protect fencers from any dangerous high voltages 7 4 Tower Lights Connection The pair of Tower Lights is an optional accessory and ...

Страница 15: ...r PC Type in the IP address 192 168 1 230 in the browser s address bar See Fig 19 6 On the page that appears on your computer see Fig 20 click on the Choose button to browse the computer s folders and select the previously saved update file of the type FA 07_0100_0201 bin Then click on Open to confirm your choice 7 Launch the software update program by clicking on Upload At the end of the operatio...

Страница 16: ...ENGLISH FAVERO ELECTRONICS SRL Page 16 16 940 M06 EN FA 07 Manual ...

Отзывы: