Favero FA-07 Скачать руководство пользователя страница 12

ENGLISH

6.4

IP addresses and checking connection status

Once all apparatuses are in position, we suggest creating a table that links each piste number to the corresponding 

FA-07’s

IP  address,   which   can   be   modified   via   programming   step   P.04   (chapter   5.2);  we   suggest   using   an   IP  address   between
192.168.000.020 and 192.168.000.254, i.e., leaving the first 9 digits the same (192.168.000) unless they are already being
used by other devices. Make sure that the IP addresses of the various apparatuses connected via LAN are all different from
one another  .
Leave the port number of all  

FA-07s

, shown in programming step P.05, at  

50100

  and modify it only in accordance with the

central management system.
The IP addresses of all apparatuses should be inserted in the central management programme. 
To show that there is an active connection status with the central system, the yellow LINK light on the 

FA-07

 will switch on

(see Fig. 15); the piste number assigned and communicated to the 

FA-07

 will appear on the graphic display panel so that its

correspondence can be verified.
If there is no reception of messages sent from the central system for over 40 seconds, the 

FA-07

 will consider the connection

concluded and will interrupt and switch off all relative indications.

6.5

Matches managed via LAN

When the 

FA-07

 recognizes that connection via LAN is active, the yellow LINK light (see  Fig. 15) will switch on and the piste

number associated to the 

FA-07

 will appear on the graphic display panel. 

Following is a description of the various phases for managing a match via LAN connection .

6.5.1 Request for a new/subsequent match

By pressing the [

Alt-1

] + [

NEXT

] keys on the remote control, first the 

FA-07

 will completely set all of its current data to zero,

then it will send a request to the central system for data regarding the subsequent match. When such information has been
received, the names and nationalities of the fencers will appear, flashing several times, on the 

FA-07’s

 graphic display panel.

If this does not happen, for example because the central system does not yet have such data, the request will have to be
repeated.
Along with  the data of the new match, please note that the central system  can also send the score, match number, and
chronometer value, etc…, for managing team competitions where the matches which immediately follow continue with the
previous scores and the match number is automatically determined by the central system. The reception of all data is also
necessary when a previously interrupted match is recalled (see chapter 6.5.4).
Information regarding the new match may include the time the match is scheduled to begin; if so, the time will be shown on
the FA-07's graphic panel.
If you do not wish to immediately begin the assigned match, in order to use the 

FA-07

 for other autonomous matches or trials

the information received should be set to zero by pressing the [

Alt-1

] + [

RESET

_

ALL

] keys. The match to run can then be

later requested.
Remember that the referee can invert the fencers’ positions via the [

Fencers

_

swap

] key on the remote control and can also

insert the reserve fencers via the [

F1

] and [

F2

] keys in a team competition.

6.5.2 Match start

If   the  

FA-07

  has   received   and   is   displaying   the   data   for   a   new   match   (e.g.,   fencers’   names,   etc…),   the   referee   can

communicate the start of the match to the central system by pressing the [

Alt-1

] + [

BEGIN

] keys on the remote control. From

that moment onwards the  

FA-07

 continuously transmits data via LAN and the “Match Running” light will switch on (see   Fig.

15) to indicate that the match is underway. 
To interrupt the match, press [

Alt-1

] + [

RESET

_

ALL

]: the F

A-07

 will switch off the “MATCH Running” light and stop sending

data to the central system. Such data may later be recovered by pressing the [

Alt-1

] + [

NEXT

] keys.

6.5.3 Match end

By pressing the [

Alt-1

] + [

END

_

final

_

approval

] keys on the remote control, the referee communicates the end of the

match to the central system. After the central system confirms receipt of such information the 

FA-07

 will consider the match

ended and switch off the “Match Running” light and the word “

END

” will be displayed for 2 seconds on the chronometer. If this

FAVERO ELECTRONICS SRL

Page 12 / 16

940-M06-EN FA-07 Manual

Red “

” light.

Indicates that the match is under way and that the 

  is  continuously  transmitting  all  match  data  through 

the Ethernet port.

Match Running

FA-

07

PRO G

Re a r m .

t im e

+

Me di ca l

V/D

Abandon

Exclusion

E N TE R

EX IT

(se c)

F 1

F2

Me di ca l

Sound

Level

F3

NEXT

PREVIOUS

V/D

Abandon

Exclusion

Yellow “

” light.

Signals  LAN communication  via the  Ethernet port,  that 
is, that the 

 recognizes an active connection with 

the central management system.

LINK

FA-07

Fig. 15: Lights indicating Ethernet connection status

Содержание FA-07

Страница 1: ...keys 6 4 5 Battery charging 8 4 5 1 Low battery indication 8 5 PROGRAMMING TEST MENUS 9 5 1 Introduction 9 5 2 Description of programming steps 9 5 3 Description of tests 9 6 OPERATION VIA LAN 11 6 1 Preliminary information 11 6 2 Software for the central system for managing competitions 11 6 3 LAN connections 11 6 4 IP addresses and checking connection status 12 6 5 Matches managed via LAN 12 6 5...

Страница 2: ...0 01 FA 07 Scoreboard without accessories Art 952 FA 07 remote control Art 858 2 5m Cable for Serial Data Art 859 15m Cable for Serial Data Art 954 Power Supply 90 264V 12Vdc 2 5A Medical Art 828 Rechargeable battery 12Vdc 7Ah Art 829 Battery charger for Art 828 battery Art 880 Doubler for SERIAL DATA Art 856 Power cord with clamps for connecting to a car battery Art 948 Carrying case for Tower Li...

Страница 3: ... purchase agreement and includes free repair of all defects found in materials or in construction the warranty does not cover delivery or transportation costs The portable power supply Art 954 provided with the FA 07 and the optional battery Art 828 are not covered by the warranty 1 4 Power supply Power supply voltage 12Vdc 10 6 14 5Vdc Consumption 0 5A typical 0 85A max without the Tower Lights 2...

Страница 4: ...s follows 1 Selected weapon and version or else temporary notification of faults or other information 2 Rearmament time 1 3 5 Man Rearmament can take place automatically after 1 3 or 5 seconds or else manually 3 Start time minutes of chronometer 4 Nationality of fencers 5 Names of fencers as with nationalities the names of the fencers appear only when the FA 07 receives the information from the ce...

Страница 5: ...See chapter 7 1 Insert the RESERVE fencer on the left side in team competitions On the FA 07 display panel the name of the fencer will be replaced by the words RESERVE The key is active when the competitions are managed via a LAN connection after confirming the match by the Alt 1 BEGIN keys Same as with F1 key but for the right side Increase the number of medical interventions for the correspondin...

Страница 6: ...p P 03 select Block Remote Control YES see chapter 5 2 Remember to unblock this function at the end of the competition otherwise future users who are not familiar with or who do not remember this function might assume that the remote control is not working properly 4 3 Remote control indications There are 2 red lights on the remote control see Fig 5 Transmission light signals each transmission If ...

Страница 7: ...f matches Fx not used Alt 1 WEAPONS effectuate the change of weapon in the same way that the corresponding key on the FA 07 keyboard does Fencers_swap inverts all the visual displays regarding the two fencers This is used when fencers change positions Alt 1 1sec decrease the value of the chronometer by 1 second to allow for corrections to be made During the last 10 seconds time decrease is display...

Страница 8: ...ed A totally depleted battery is recharged in circa 7 hours while a charged battery lasts circa 300 hours of competition time We suggest charging the battery at least once a year if the remote control is not used 4 5 1 Low battery indication If the remote control battery is low the FA 07 s graphic display panel will switch off for a brief moment and the message Remote Control Battery Low will appe...

Страница 9: ...meter P 04 IP 000 000 000 000 254 254 254 254 When a LAN connection is used each apparatus must have a different IP address We suggest using a number from 192 168 000 020 to 192 168 000 254 if not already in use by other devices Use the key to select the number you wish to modify and the keys and to modify it P 05 Port number 01025 65535 This number is used for connection to the LAN We suggest tha...

Страница 10: ...all the contact combinations that take place between fencers It can also be useful to the user for distinguishing if the indications of faults are due to failure of the internal circuits or to defects in the external connections The display panel see Fig 12 shows 12 values in the three columns to the left and in the far right column the corresponding values Higher H Middle M Lower L and Deviation ...

Страница 11: ... Alt 1 PREVIOUS for the data from the previously concluded match in order to correct any possible errors The central system decides whether to accept the request or not For more information on management of the match via LAN see chapter 6 5 6 2 Software for the central system for managing competitions Communication between the central system and the various FA 07 apparatuses connected to the LAN t...

Страница 12: ...alue etc for managing team competitions where the matches which immediately follow continue with the previous scores and the match number is automatically determined by the central system The reception of all data is also necessary when a previously interrupted match is recalled see chapter 6 5 4 Information regarding the new match may include the time the match is scheduled to begin if so the tim...

Страница 13: ...em has been informed of the match end and the MATCH Running light has been switched off a new match can be requested as described in chapter 6 5 1 6 5 4 Correcting a previously sent match Via the Alt 1 PREVIOUS keys of the remote control the referee can ask the central system for the data pertaining to the previously concluded match in order to make eventual corrections The central system will dec...

Страница 14: ...Ethernet port This port allows the FA 07 to be connected A directly to a PC for updating software as described in chapter 8 B to a LAN in order to manage the entire competition via the central system as described in chapter 6 The Ethernet port has a 1500V isolation to protect fencers from any dangerous high voltages 7 4 Tower Lights Connection The pair of Tower Lights is an optional accessory and ...

Страница 15: ...r PC Type in the IP address 192 168 1 230 in the browser s address bar See Fig 19 6 On the page that appears on your computer see Fig 20 click on the Choose button to browse the computer s folders and select the previously saved update file of the type FA 07_0100_0201 bin Then click on Open to confirm your choice 7 Launch the software update program by clicking on Upload At the end of the operatio...

Страница 16: ...ENGLISH FAVERO ELECTRONICS SRL Page 16 16 940 M06 EN FA 07 Manual ...

Отзывы: