8.4. Technical information
Measurement range
Illumination intensity E
20000 lx
Infrared spectrum
200,00 W/m²
Ultraviolet spectrum
20000 mW/m²
Flicker rate
0...100 %
Calculation type
Ripple content according to SBM-2015
Flicker% according to IESNA
Flicker frequency
50 Hz...400 kHz
Resolution
Illumination intensity E
1 lx
Infrared spectrum
0,01 W/m²
Ultraviolet spectrum
1 mW/m²
Flicker rate
1 %
Flicker frequency
5 Hz
Audio functions
Audible range
20 Hz...20 kHz
Ultrasonic
10 kHz...400 kHz
Display
illuminated double-spaced LCD
Display functions
Illumination intensity, Peak-Hold, infrared, ultraviolet
flicker rate, flicker frequency
Ínterface
(LM10L/LS)
USB 2.0
Voltage output
(LM10S/LS)
quadruple 0...2000 mV
Power supply
2 x Mignon AA
Dimensions
120x79x28 mm
Ambient temperature
0...+40 °C
Measuring probe VL10
Spectral sensitivity
480...660 nm
Spectral approximation
V(λ)
Measuring probe IR10
Spectral sensitivity (λ
0,5
)
790...1050 nm, 940 nm
max
Measuring probe UV10
Spectral sensitivity (λ
0,5
)
220...365 nm, 350 nm
max