Step III. 

Testing the Telephone Network

  

A)  Polarity and Line Voltage

 

Lightly press the Polarity button.  If no 
indication is shown by the Red or Green 
Polarity LED’s and the Voltage display 
LED’s, you may not have the correct 
Line selected.  Gently slide the Line 
Select Switch to the other position and 
repeat this step.  If you still have no 
indication, then neither line is working.  
There may be a loose connection, 
broken wire, or short in the wiring.  
Correct Polarity is shown as Green, 
reversed as Red. (Equipment such as 

modems, FAX machines, and some 
tone-dialing telephones may not work 
properly with a reversed polarity line.) 

B)  Loop Test (Loop Current)

 

If a Polarity indication was given, lightly 
press the button shown for Loop Test. 
This will simulate an “off-hook” 
telephone. The Red LED will light 
brightly if sufficient power is available to 
operate a telephone or other device.  If 
the LED does not shine or is very dim, 
either another device is in use or the line 
has a partial fault.  No Telephone 
Network Device can properly operate 
with no or insufficient Loop Current. 

C)  Line / Ring Voltage Display

 

This display indicates three states of line 
condition.  With no button pressed, the 
BT-10 is in a stand-by mode waiting for 
a Ring signal.  Use the chart on the back 
of the BT-10 as a reference.  

When the Polarity button is pressed, 
this display will also show the Network’s 

Line Voltage.  A properly installed and 
balanced network will always be 
indicated with the Green LED.  Yellow 
indicates a potentially damaging 
Network, Red a poor or damaged 
Network needing repair. 

D)  Testing Telephone line cords.

 

After verifying proper Network 
operation, remove the adapter and 
replace with a line cord.  Repeat Step 
III A & B.  

A good line cord should not 

change the results of your previous 
testing.

 

  

Caution Do Not Exceed 

Caution Do Not Exceed 

Caution Do Not Exceed 

Caution Do Not Exceed     

150 VRMS to the Test Jack.

150 VRMS to the Test Jack.

150 VRMS to the Test Jack.

150 VRMS to the Test Jack.

  

The BT-10 should not be permanently 
connected to a telephone network.  Use 
it only to test the network and then 
disconnect from the telephone wiring. 

Helpful Note for

 

common wiring

Line 1 Tip/Ring as Red and Green. 
Line 2 Tip/Ring as Black and Yellow. 

 

©

Faunus, Inc.