FastVision FASTCAMERA Series Скачать руководство пользователя страница 31

31 

 

anti-static protective bags.  Then pack the product(s) securely in the original 
shipping materials, if possible, and ship to: 

 

FastVision, LLC. 

71 Spit Brook Rd., Suite 210 

Nashua, NH  03060 

USA 

 

Clearly mark

 the outside of your package: 

Attention 

RMA #XXX

 

Remember to include your return address and the name and number of the person who 
should be contacted if we have questions. 

14.2 Reporting 

Bugs 

We at FastVision are continually improving our products to ensure the success of your 
projects.  In addition to ongoing improvements, every FastVision product is put through 
extensive and varied testing.  Even so, occasionally situations can come up in the fields that 
were not encountered during our testing at FastVision. 

If you encounter a software or hardware problem or anomaly, please contact us immediately 
for assistance.  If a fix is not available right away, often we can devise a work-around that 
allows you to move forward with your project while we continue to work on the problem 
you’ve encountered. 

It is important that we are able to reproduce your error in an isolated test case.  You can help 
if you create a stand-alone code module that is isolated from your application and yet clearly 
demonstrates the anomaly or flaw. 

Describe the error that occurs with the particular code module and email the file to us at: 

 

[email protected]

 

 

We will compile and run the module to track down the anomaly you’ve found. 

If you do not have Internet access, or if it is inconvenient for you to get to access, copy the 
code to a disk, describe the error, and mail the disk to Technical Support at the FastVision 
address below.  

If the code is small enough, you can also: 

FAX the code module to us at 603-891-1881 

If you are faxing the code, write everything large and legibly and remember to include your 
description of the error. 

When you are describing a software problem, include revision numbers of all associated 
software. 

For documentation errors, photocopy the passages in question, mark on the page the 
number and title of the manual, and either FAX or mail the photocopy to FastVision. 

Remember to include the name and telephone number of the person we should contact if we 
have questions. 

 

 

Содержание FASTCAMERA Series

Страница 1: ...1 FASTCAMERA SERIES FASTCAMERA40 USER S MANUAL 30002 50040...

Страница 2: ...2...

Страница 3: ...040 Revision History 1 0 January 20 2003 1 1 March 26 2003 1 2 March 30 2003 1 3 April 9 2003 Trademarks FastVision is a registered trademark of FastVision LLC Channel Link is a trademark of National...

Страница 4: ...4...

Страница 5: ...3 POWER REQUIREMENTS 11 4 TIMING 11 5 TRIGGER MODES 11 6 READ OUT MODES 11 7 STANDARD CAMERA DATA FLOW 15 8 THE STANDARD CAMERA FUNCTIONALITY 15 9 USB CAMERA OPTION 23 10 CAMERA CONTROL PROGRAM 24 11...

Страница 6: ...6...

Страница 7: ...mmable logic in the camera FastVision or the Customer can customize the size and content of the FPGAs and memory in the camera to contain many different features processing algorithms and storage sche...

Страница 8: ...SRAM for ultra fast processing Optional additional DDRAM and increased FPGA size for additional processing capability Trigger able electronic rolling shutter C mount lens 2 1 FastCamer40 Image Sensor...

Страница 9: ...ref 39 5m m 74 0m m 0 ref 7m m 132m m FastCam era40 Side View 12 7m m FastCam era40 Front View FastCam era40 B ottom View 7m m 0 ref 0 ref 39 5m m 79 0m m FASTCAM ERA40 CASE AND M O UNTING DIM ENSIO...

Страница 10: ...N 17 CL1_TXOUT2P 5 CL1_TXCLKOUTN 18 CL1_TXCLKOUTP 6 CL1_TXOUT3N 19 CL1_TXOUT3P 7 SERTCP 20 SERTCN 8 CC1N 21 SERTFGP 9 CC2P 22 CC1P 10 CC3N 23 CC2N 11 CC4P 24 CC3P 12 SERTFGN 25 CC4N 13 Ground 26 Groun...

Страница 11: ...lt input to 3 3 2 5 and 1 8 volts 4 TIMING Camera Clock is configurable from 25 to 85 MHz depending on the application Pixel data is valid when LVAL FVAL and DVAL are true Minimum two clocks LVAL and...

Страница 12: ...s 4 n 3 Four Taps 8 bits Medium 8 CL1_B 1 0 CL1_A 7 0 4 n 0 CL1_B 5 4 CL1_C 7 0 4 n 1 CL2_C 1 0 CL2_B 7 0 4 n 2 CL2_C 4 5 CL2_A 7 0 4 n 3 Four Taps 10 bits Medium 9 CL1_A 7 0 pixels 5 n 0 CL1_B 7 0 pi...

Страница 13: ...6 CL3_FVAL CL3_LVAL CL1_DVAL CL3_SP CL2_B 7 6 CL2_B 3 2 8 n 7 Eight Taps 10 bits Full 15 CL1_A 7 0 16 n 0 CL1_B 7 0 16 n 1 CL1_C 7 0 16 n 2 CL2_A 7 0 16 n 3 CL2_B 7 0 16 n 4 CL2_C 7 0 16 n 5 CL3_A 7...

Страница 14: ...2 CL2_SP CL2_B 7 6 CL2_ 3 2 G 4 n 3 CL3_SP CL3_B 7 6 CL3_ 3 2 CL4_SP CL4_B 7 6 CL4_ 3 2 B 4 n 3 12 Taps 10 Bits Color 5 Camera Links 17 CL1_B 1 0 CL1_A 7 0 CL1_B 5 4 CL1_C 7 0 CL2_B 1 0 CL2_A 7 0 CL2...

Страница 15: ...be used for image averaging In this mode Images are summed into a 32 bit per pixel buffer which can be read out at any time CC2 and or cleared CC3 CC1 CC2 and CC3 can be replaced by Serial Commands or...

Страница 16: ...eparate amplifiers and converters for each column in the sensor for the FastCamera 40 that is 2352 converters At the same time a line is read out and reset from the sensor a different line can be rese...

Страница 17: ...gain values are computed in the simplest case the pixel values and the ratio with 75 of full scale 191 8 bit or 768 10 bits determines the gain Note It is assumed that you are trying for a uniformly...

Страница 18: ...g in the image capture will never stop A reset is required to re arm the trigger and delay process 8 3 3 Image summing memory mode In this mode the memory is divided up into buffers the size of the se...

Страница 19: ...er until the camera sends a 0x3f you will be back in sync without effecting the camera state 8 6 3 0x01 ADC settings Serial Command If you need to adjust the control voltages of the sensor then use th...

Страница 20: ...2 0x20 Set Trigger Mode Serial Command This allows you set the trigger mode CC1 the options are free run CC1 edge or CC1 level See the section on exposure above 8 6 13 0x30 Write Flash Memory Serial C...

Страница 21: ...9 8 5 VREF2 7 0 6 VREF2 9 8 7 VTEST 7 0 8 VTEST 9 8 9 VREF3 7 0 10 VREF3 9 8 11 VBIAS1 7 0 12 VBIAS1 9 8 13 VREF4 7 0 14 VREF4 9 8 15 VBIAS2 7 0 16 VBIAS2 9 8 17 VLN1 7 0 18 VLN1 9 8 19 VBIAS3 7 0 20...

Страница 22: ...ggered If data byte 0 image readout will occur as soon as an image is ready 0x08 0 Clear FIFO Memory 0x09 1 Set Read out mode See section above 0x10 0 Trigger Image collection 0x11 2 Trigger delay cir...

Страница 23: ...ramegrabber if it supports the standard Camera Link DLL or may be used with the USB port in situations where the camera link serial port is not available or too slow In order to use this option you mu...

Страница 24: ...you an idea of what you need to operate the camera with a PC 11 1 USB operation In this mode of operation needs the following items The camera and a lens A power supply for the camera A USB cable Fas...

Страница 25: ...ns Computer USB Cable 11 1 2 The software connections are USB Device In Camera Your Software Library DLL Or ActiveX Control Operating System Provided USB Drivers FastVision Provided USB Device Driver...

Страница 26: ...egrabber software All of this can be supplied by FastVision 11 2 1 The hardware connections are Camera Lens Your Computer Power Supply FastVision Provided Frame Grabber 1 or 2 Camera Link Cables 11 2...

Страница 27: ...11 3 1 The hardware connections are Camera Lens Your Computer Power Supply Third Party Provided Frame Grabber 1 or 2 Camera Link Cables 11 3 2 The software connections are Camera Serial And Channel Li...

Страница 28: ...e hardware installation to make sure that the system is properly installed _____ Go back over the software installation to make sure you have installed all necessary software _____ Run the Installatio...

Страница 29: ...Vision Technical Support you feel your hardware or software is not functioning properly you can return the product to FastVision for service or replacement Service or replacement may be covered by you...

Страница 30: ...30 All of this information will be logged into the RMA report so it s there for the technician when your product arrives at FastVision Put boards inside their...

Страница 31: ...ountered It is important that we are able to reproduce your error in an isolated test case You can help if you create a stand alone code module that is isolated from your application and yet clearly d...

Страница 32: ...FastVision LLC 131 Daniel Webster Highway 529 Nashua NH 03060 USA Telephone 603 891 4317 FAX 603 891 1881 Web site http www fast vision com Electronic Mail sales fast vision com support fast vision c...

Отзывы: