2.3.4 Data Connector J3
Pin Signal
Pin Signal
1 Ground
14 Ground
2 CL4_TXOUT0N
15 CL4_TXOUT0P
3 CL4_TXOUT1N
16 CL4_TXOUT1P
4 CL4_TXOUT2N
17 CL4_TXOUT2P
5 CL4_TXCLKOUTN
18 CL4_TXCLKOUTP
6 CL4_TXOUT3N
19 CL4_TXOUT3P
7 Application
Specific
I/O (P)
20 Application
Specific
I/O (N)
8 CL5_TXOUT0N
21 CL5_TXOUT0P
9 CL5_TXOUT1N
22 CL5_TXOUT1P
10 CL5_TXOUT2N
23 CL5_TXOUT2P
11 CL5_TXCLKOUTN
24 CL5_TXCLKOUTP
12 CL5_TXOUT3N
25 CL5_TXOUT3P
13 Ground
26 Ground
3 POWER
REQUIREMENTS
Power requirements are a strong function of the application, Camera is 15 Watts worst case, 5 to
10 Watts typical. Low noise +5 Volt input recommended. Internally the camera has high
frequency switching supplies that convert the 5 volt input to 3.3, 2.5 and 1.8 volts.
4 TIMING
Camera Clock is configurable from 25 to 85 MHz depending on the application.
Pixel data is valid when LVAL, FVAL and DVAL are true.
Minimum two clocks LVAL and FVAL inactive between lines and frames.
CC4 reserved for application specific needs.
5 TRIGGER
MODES
Trigger modes are selected by serial commands.
Free Running, camera generates frames without triggers.
CC1 Positive edge triggered.
CC1 When active, expose, falling edge reads out the sensor.
6 READ OUT MODES
The camera can be read out with 1,2,3,4, or 5 camera links, the serial port (for the really patient),
or via the USB port. Only image data from the selected ROI is sent. The camera can be
configured to read out when the image is taken, to read out from memory on serial command or
the CC2 positive edge.
Note:
The modes that use 3 channel links or less are according to the Camera Link Standard