![Fastrax Hellfire 900 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fastrax/hellfire-900/hellfire-900_installation-operation-and-maintenance-instructions-manual_3597482013.webp)
13
13
C
on
tr
ols
&
In
dic
ati
on
s
E.
CONTROLS & INDICATIONS
E.1 AAR Signal Wiring - For non SCADA installations
Table 4 – AAR Signal Wiring
Terminals
Label
Description
A1 - A2
REMOTE START
A contact closure across these terminals starts the heater when the heater is in REMOTE RTC mode.
A3 - A4
RUN
Dry contact closes to provide a run indication.
A5 - A6
ALARM
Dry contact closes to provide alarm indication.
A7 - A8
FORCE OFF
Default is closed. If FORCE OFF function is desired, remove shorting link and replace with customer
supplied relay contact. Open contact disables heater.
A9 - A10
TANK VALVE
These terminals are intended to operate a 120V AC gas supply solenoid shut off valve. They energize
when the motor contact closes.
A11
RS-485 (+)
Communications, RS-485 positive terminal (for RCMS operation only)
A12
RS-485 (-)
Communications, RS-485 negative terminal (for RCMS operation only)
E.2 Controller
1.
The controller manages the operation of the heater and
allows it to either operate on its own or be part of a
network of heaters.
2.
The controller monitors various inputs, controls the heater
functions, communicates status and provides indication
LEDs.
3.
The controller is DIN rail mounted and all wiring
connections are made with plug connectors to allow quick
replacement in the event of a failure.
4.
With the addition of the EMS package, a stand alone
heater can operate automatically based on weather
conditions, or when connected to a network, act as a
weather station providing input to a SCADA system.
5.
Its’ RS-485 serial communications port allows the heater
to interface with SCADA systems, and be operated and
managed by a Remote Control and Monitoring System,
such as the Fastrax®
RCMS.
NOTE:
Controllers are
not
interchangeable between HELLFIRE
400 (24V AC) and HELLFIRE 900 (120V AC).
Содержание Hellfire 900
Страница 26: ...26 26 Figure 3 155 Clearance Figure 2 140 Clearance Installation...
Страница 27: ...27 27 Figure 4 155 Clearance Turned 90 Degrees Installation...
Страница 37: ...37 37 Heater Specifications THERMON HEATING SYSTEMS INC H 9 SchematicsMaintenance...
Страница 38: ...38 38 Heater Specifications THERMON HEATING SYSTEMS INC...
Страница 39: ...39 39 Heater Specifications THERMON HEATING SYSTEMS INC...
Страница 40: ...40 40 Heater Specifications THERMON HEATING SYSTEMS INC...
Страница 41: ...41 41 Heater Specifications THERMON HEATING SYSTEMS INC...
Страница 42: ...42 42 Heater Specifications THERMON HEATING SYSTEMS INC...
Страница 54: ...54 54 NOTES...
Страница 55: ...55 55 NOTES...