The instrument is automatically self-leveled and fast with installed inner compensators magnetically
insulated. The self-leveling range of the instrument is /- 4
o
.
No level range sensors are automatic and cause flashing of the laser beam when the instrument is
outreach of the self-level range.
The multifunctional on/off button
1.
By pressing this button the tool is switch on and the self-leveling horizontal laser line is
displayed.
2.
Second press of this button causes display of the vertical line.
3.
After another press the self-leveling cross set at an angel 90
o
is displayed.
4.
One more press of the button causes switching to the manual mode. In this mode the
self-leveled compensator is switched off, thanks to the fact the cross set at an angle 90
o
does not cause flashing of the laser beam.
5.
The instrument is switched off as a result of another press the button.
* Using
- Place the instrument on an even and smooth surface or set it up horizontally on the tripod.
- Turn on the laser level by pressing the button on/off. There will be displayed the horizontal laser
line. Check if the indicator light green which means that the tool work out in self-level range.
- If the indicator and the laser line are flashing, change a position of the instrument to set the self-
leveling range and the LED indicator turns green.
- Select the requested line by pressing a multifunction button on/off several times.
- After it press the on/off button until the instrument will turn off.
USING THE TRIPOD
The tripod consist of 3 parts length 1 m each. The “twist lock” mechanism (locking by turning) and the
upper part are equipped with a spring which provide precise fit to the ceiling. Before the first use set
the ceiling plate to the ball joint.
Place the rubber flange on the floor and press an individual section on the adequate length. Every
section can be unlock or lock by twisting it in the right direction. When the tripod will stand in vertical
position, touching a celling, increase height to lean it firmly against the ceiling and then lock it. The
tripod will be
conscientiously placed between a floor and a ceiling.
Attach the tripod fixing handle “C” with the fixing handle of the device “B” matching 3 slots “C” from
the back of an instrument for adequate insets in the fixing handle of the pole and move down a handle
of the device to lock it in the appropriate place.
Screw handles set to a tripod by opening 1c and 2c until it will be matched to the tripod. Set it at the
required height.
Set the instrument to an ensemble of handles by using a fastening screw 1b. Make sure it adheres
precisely to the handle.