11
12
feature. If utilizing this feature the screw gun will automatically
turn off between drives and start upon depressing the nose piece.
FastenMaster recommends utilizing a continuous drive mode or
“auto on” mode when using the
PAMFast
Autofeed tool.
• Between drives it is critical that the tool is fully lifted from the
surface to allow the nose piece to completely recoil.
(Fig 8-11)
6) Loading Fasteners
• Feed the fastener strip into the belt guide
and load into the 1-3” attachment.
(Fig
5-6)
. The fastener strip advances on the
down stroke, so the first screw should be
one spot prior to the drive position.
• If it is necessary to remove screws
from the
PAMFast
tool, pull the strip
forward, not backwards (Fig.7).
I
Warning
Only use genuine PAMFast
collated screws. Use of any other brand
fastener is not advised and will void the
limited warranty on your PAMFast tool.
7) Driving Fasteners
•
Confirm that the motor is set to run in the forward
direction.
Set the screw gun to “auto on” or “continuous” drive
mode. Refer to screw gun manufacturer’s operating instructions.
• With the motor running at full speed, apply and maintain
continuous pressure to drive the fastener until the drive bit
automatically disengages. For proper drive, it is critical that
the operator applies continuous pressure to fully depress
the nose piece when driving the fastener.
• When driving multiple fasteners consecutively, keep the motor
power on between drives. Some screw guns offer an “auto on”
Fig. 5
Fig. 6
Fig. 7
Operating Instructions
(continued)
Operating Instructions
(continued)
Fig. 8
Fig. 9
Fig. 10
Fig. 11
For a video demonstration on how to setup and operate the
PAMFast
Autofeed tool visit: