15
7.1.2 Protection functions and LED blinking times
7.2 Setting Up Parameters
Alarm LED blinking (ex: Speed error)
RS-232C serial communication port of a computer is used to set up various parameters of the
motor driver. The set-up program is supplied with the product on a companion CD. It is
recommended to make a copy of the program in any folder on your computer. Then please
execute the program, named “EzStep Setup.exe”, from the folder.
Please select an appropriate Prot No. and press
icon. Then it will display the various
parameter values previously stored in the driver.
: Display the parameter values stored in the
driver
: Store the parameter values
displayed on the screen into the
driver
Blinking Times
Protection
Conditions
1
2
3
5
9
Overcurrent
Overspeed
Overheat
Lowpower
Out of Synchronization
1
0.5s
2
3
1
2
3
Excessive current flowed into a motor
Motor speed exceeded 3000 RPM
Abnormally, motor did not followed pulsed inputs
Internal temperature of a motor driver exceeded 55
℃
Power source voltage is below 20 volts
2.0s