19) TOKENS & COUPONS
The machine will recognize coupons and tokens as free vends when the Promotional Vend feature is enabled. Item
and price will be noted as a free vend in the DEX report.
Display
Programming Instructions
19) TOKENS & COUPONS
a) Press to the #=Yes key to enter this menu.
*=Next
D-Back
#=Yes
Promotions: Off
*=Scroll
A=Abort
#=Enter
Promotions: YES
c) Press #=Yes to confirm selection.
Accept?
*=NO
#=Yes
b) Press the *=SCRL key to turn the Promotions feature off
and on. Scroll to Yes and press the #=ENTR key to enter.
Display
Programming Instructions
20) FIELD TEST
YES
a) Press to the #=Yes key to begin diagnostics. Failures
will be displayed after each failed test.
*=Next
D-Back
#=Yes
Input Monitor…..
IG Ice Cream Machine
b) The type of motor used in the machine is displayed. The
original style motor is the MK DC Motor. The latest style
motor is the IG DC Motor.
Input Monitor…..
c) Manually moving or engaging component parts activates
the input monitor, displaying the component and corre-
sponding sensor/switch state (LOW=Open/Positive,
HIGH=Closed/Negative).
Airflow Detect
HIGH/LOW
Press the VAC button to test air flow in the vacuum valve
Front/Back Encoder
HIGH/LOW
Move the robot in the Front/Back direction
Left/Right Encoder
HIGH/LOW
Move the robot in the Left/Right direction
Up/Down Encoder
HIGH/LOW
Move the robot in the Up/Down direction
Left/Right Home
HIGH/LOW
Move the robot off the Left/Right position
Front/Back Home
HIGH/LOW
Move the robot off the Front/Back position
Up/Down Home
HIGH/LOW
Move the robot off the Up/Down position
Freezer Close
HIGH/LOW
Open and close the Freezer Lid
Freezer Encoder
HIGH/LOW
Move the Freezer Lid Actuator Arm
Freezer Open
HIGH/LOW
Move the Freezer Lid Actuator Arm in the full up position
Press Motor Keys
Or # To Continue
d) Press the #Key on the Customer Keypad to advance
screen. Press Left, Right, forward, Back, Up and Down on
the Service Keypad to test motor function.
Testing Real Time clock
- - -
Keyboard/Buzzer Test
Press the A Key
e) Press the “A” Key to test the Customer keypad.
20) FIELD TEST
The self-diagnostic feature allows for quick troubleshooting through a sequence of system checks. Press the VAC button on the
service keypad and run Field Test if the machine goes into OOS (Out Of Service). This allows the suspected problem area to be
tested. After the self-diagnostic sequence is complete, press any button to return to the error. Press RESET to clear any errors.
A-28