• Contrast: set screen contrast from 1-11.

27

To access “Advanced Settings”, hold finger 5 
seconds on icon.  A warning will appear:

Caution: Incorrect configuration 
can damage your system, continue? 
YES NO

25

Displays filter usage in days and resets filter timer.

26

Set Screen Options:

• Daylight Time (ON/OFF): activate only if you are 

located in a “Daylight Savings Time” zone.

• Reverse: Select between dark background (ON) 

or light background (OFF)

• Night Reverse: Select between ON: Automatically 

reverses screen background for comfortable 
viewing at night (from 9PM to 6AM) OFF: screen 
background determined by “Reverse” function 
setting.

• You will be prompted to: (first time user) Enter 

the default PIN

• Enter your new PIN Re-enter your new PIN

• There are two modes of password protection:  Full 

Lock and Partial Lock

• The full lock Function does not allow any changes 

unless the user enters the PIN

• Partial Lock allows you to change only the 

temperature setpoint without entering a PIN.

32

Enter “Installer Message” (up to 42 characters) to
appear at programmable intervals, see 17.

28

Turn “Filter Monitor” ON or OFF; if ON enter the 
filter replacement interval.

29

Enter HVAC system consumption parameters 
rounded off to kW; see 26 (Typically: Fan 1kW; Heat
Pump 1kW/ton; Furnace 5-30 kW, 7-9¢/kW)

30

Change thermostat temperature display units (ºF or ºC).

31

Turn “Security” ON or OFF (Default Security PIN =
1111) and select the security level: The security 
settings allow you to protect your thermostat 
thermostat from unauthorized use.

• Turn Security On or Off ( Default pin 1111)  

31

32

28

29

30

MENU 

PAGE

TO ACCESS THE MENU PAGE, 

SIMPLY TOUCH 

FROM THE CONTROL PAGE.

ADVANCED SETTINGS 

PAGE 1

Содержание TS21

Страница 1: ......

Страница 2: ...premium comfort and temperature accuracy 1 degree F Simple to use Set and Forget with an easy to use menus so straightforward no instruction manual is needed 7 day Programmable with 4 events each day...

Страница 3: ...LL 1 Make sure to turn off the power supply located at the electrical service panel All heating and cooling units should be OFF 2 Remove the cover plate by pulling up the cover from the left or right...

Страница 4: ...e above colors are standard in HVAC industry The wiring should be confirmed before installation WIRING TABLE CONFIGURATION Y1 Y2 W2 OB W R C R H G 1 Stage Cooling 2 Stage Heating Air Conditioner 2 Sta...

Страница 5: ...AT 24V RED Heat WHT Fan GRN AC YLW COMMON BLUE 24V RED Heat2 Heat1 WHT Fan GRN AC YLW COMMON BLUE WIRING DIAGRAM ONE AC TWO AC 24V RED Fan GRN AC YLW COMMON BLUE AC2 YLW 24V RED Fan GRN AC1 YLW COMMON...

Страница 6: ...lves ORG Heat 1 WHT Fan GRN HP YLW COMMON BLUE HP 2 24V RED Reverse Valves ORG Fan GRN HP 1 YLW COMMON BLUE ONE HEAT PUMP ONE HEAT PUMP ONE HEAT WIRING DIAGRAM 24V RED Reverse Valves ORG Fan GRN HP YL...

Страница 7: ...TWO TRANSFORMERS HEAT TRAN CUT COOL TRAN WIRING DIAGRAM AC TWO STAGE FURNACE ONE TRANSFORMER 24V RED 2nd Stage Heat 1st Stage Heat WHT Fan GRN AC YLW COMMON BLUE HEAT TRAN WIRING DIAGRAM...

Страница 8: ...d In Auto mode touch Heat Cool button Heat or Cool will flash once selected then raise or lower set points as desired 14 Temperature Control Mode select between Heat Cool Auto Emergency Heat 15 Thermo...

Страница 9: ...te Adjust the Heat or Cool temperature setpoint The Vacation Mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation Mode is active the suit...

Страница 10: ...your new PIN There are two modes of password protection Full Lock and Partial Lock The full lock Function does not allow any changes unless the user enters the PIN Partial Lock allows you to change o...

Страница 11: ...OTE Number of stages depends on your system see 33 34 40 Reverses the Heat Pump OB Valve contact manufacturer dependant 34 36 33 35 33 Select system heating and or cooling equipment Heat Pump 2 stage...

Страница 12: ...ss compressor wear in the case where the necessary temperature set point is not met see 37 38 39 Set to 00 to disable 41 42 HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd st...

Страница 13: ...at and compressor contactors can supply enough current to power the thermostat with only 4 wires if you cannot hook up the C wire another possible solution is to connect two 250 ohm 10 watt resistors...

Страница 14: ...ON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY FAST PARTS DIVISION INTERNATIONAL COMFORT PRODUCTS LLC AND ITS SUPPLIERS Disclaimer NEITHER FAST PARTS DIVISION INTERNATIONAL COMFORT PRODUCTS...

Страница 15: ......

Отзывы: