background image

INSTRUCTION

MANUAL

TS21 

2 Heating and 1 Cooling

Содержание TS21

Страница 1: ......

Страница 2: ...premium comfort and temperature accuracy 1 degree F Simple to use Set and Forget with an easy to use menus so straightforward no instruction manual is needed 7 day Programmable with 4 events each day...

Страница 3: ...LL 1 Make sure to turn off the power supply located at the electrical service panel All heating and cooling units should be OFF 2 Remove the cover plate by pulling up the cover from the left or right...

Страница 4: ...e above colors are standard in HVAC industry The wiring should be confirmed before installation WIRING TABLE CONFIGURATION Y1 Y2 W2 OB W R C R H G 1 Stage Cooling 2 Stage Heating Air Conditioner 2 Sta...

Страница 5: ...AT 24V RED Heat WHT Fan GRN AC YLW COMMON BLUE 24V RED Heat2 Heat1 WHT Fan GRN AC YLW COMMON BLUE WIRING DIAGRAM ONE AC TWO AC 24V RED Fan GRN AC YLW COMMON BLUE AC2 YLW 24V RED Fan GRN AC1 YLW COMMON...

Страница 6: ...lves ORG Heat 1 WHT Fan GRN HP YLW COMMON BLUE HP 2 24V RED Reverse Valves ORG Fan GRN HP 1 YLW COMMON BLUE ONE HEAT PUMP ONE HEAT PUMP ONE HEAT WIRING DIAGRAM 24V RED Reverse Valves ORG Fan GRN HP YL...

Страница 7: ...TWO TRANSFORMERS HEAT TRAN CUT COOL TRAN WIRING DIAGRAM AC TWO STAGE FURNACE ONE TRANSFORMER 24V RED 2nd Stage Heat 1st Stage Heat WHT Fan GRN AC YLW COMMON BLUE HEAT TRAN WIRING DIAGRAM...

Страница 8: ...d In Auto mode touch Heat Cool button Heat or Cool will flash once selected then raise or lower set points as desired 14 Temperature Control Mode select between Heat Cool Auto Emergency Heat 15 Thermo...

Страница 9: ...te Adjust the Heat or Cool temperature setpoint The Vacation Mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation Mode is active the suit...

Страница 10: ...your new PIN There are two modes of password protection Full Lock and Partial Lock The full lock Function does not allow any changes unless the user enters the PIN Partial Lock allows you to change o...

Страница 11: ...OTE Number of stages depends on your system see 33 34 40 Reverses the Heat Pump OB Valve contact manufacturer dependant 34 36 33 35 33 Select system heating and or cooling equipment Heat Pump 2 stage...

Страница 12: ...ss compressor wear in the case where the necessary temperature set point is not met see 37 38 39 Set to 00 to disable 41 42 HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd st...

Страница 13: ...at and compressor contactors can supply enough current to power the thermostat with only 4 wires if you cannot hook up the C wire another possible solution is to connect two 250 ohm 10 watt resistors...

Страница 14: ...ON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY FAST PARTS DIVISION INTERNATIONAL COMFORT PRODUCTS LLC AND ITS SUPPLIERS Disclaimer NEITHER FAST PARTS DIVISION INTERNATIONAL COMFORT PRODUCTS...

Страница 15: ......

Отзывы: