4

Part #??? 

Revised ?????? 

FAST™ 

3400 Democrat Rd. 

Memphis, TN  38118 

Phone:  (901) 260-3278 Fax:  (901) 366-1807 

www.fuelairspark.com 

 

Part # FAST4-160 

Revised 11/30/09 

FAST™ 

3400 Democrat Rd. 

Memphis, TN  38118 

Phone:  (901) 260-3278 Fax:  (901) 375-3408 

www.fuelairspark.com 

R18 / R19 (rotaries without detents) 

R18 and R19 settings are only required for Onboard mode. They are not used with the optional Remote or PC 
software. These can be set fully counter-clockwise (minimum setting), fully clockwise (maximum setting), or 
any position in between. 
 

 

Setting Resolution

Min 

(full ccw) 

(position 1) 

Max 

(full cw) 

(position 3) 

R18 

Rev Limit 100’s 

(RPM) n/a 0 900 

R19 

Vacuum advance 

(°) n/a 

20 

 

Rev Limiter  

SW4 and R18 are both used to set the rev limiter in Onboard mode. Adding the two settings together gives the 
rev limit.  For example… 
 

SW4 : position 6 = 6,000 RPM 
R18 : center of rotation = 450 RPM.   
Together, they set the rev limit to 6,450 RPM. 

 

Vacuum Advance 

The vacuum advance feature adds an adjustable amount of timing on top of the base timing curve. The full 
amount is added at lower load and phased out as load increases. The MAP sensor must be installed (harness 
plugged into sensor and a vacuum line run from the sensor to the intake manifold) for this feature to work 
properly. In Onboard mode, R19 can be turned fully counter-clockwise to disable the vacuum advance feature. 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
Status LED 

The Status LED on the XIM™ will… 

 

Flash briefly once a second to confirm XIM™ is set for Standalone operation 

 

Flash an even on/off pattern when started up in flash mode (blue “Flash” wire grounded at key-on.  
Used to update firmware in XIM™.) 

 
Tach Output 

Pin 30-A3 is a 12V square wave tach output. It is available as a loose Brown/white wire and at pin F of the 
“CAM/HALL EFFECT” connector.

 

 

 

 

Manifold Pressure

73 kPa 

Adde

d Tim

ing 

R19: Vacuum Advance 

87 kPa 