Fast-Stat 1000 Скачать руководство пользователя страница 4

 

Page 4 of 5

                        Specifications subject to change without notice                                                      

Nordic Technology Ltd            

www.fast-stat.com

 

 

Model 1000 used to extend wiring to a 2-stage condenser using 2- Model 1000's.
                                 "Grounded Commons" wiring method.

C
R

W

Purple

Yellow

Green

Thermostat

Sender

Purple

Thermostat
    Cable

Yellow

Green

G

Y1

C

R

G

W

Transformer

  Fan 
Control

  Heat 
Control

Stage 1

Furnace /
Air Handler

C

Condenser

R

Y1

Red

Y2

Stage 2

Y1 Y2

  Existing 
condenser 
  cable

Y2

Receiver

F

A

S

T

-S

T

A

T

1

0

0

0

Purple
Black

Receiver

F

A

S

T

-S

T

A

T

1

0

0

0

Yellow

Green

Red

Control 
Board

Black

Connect indoor & outdoor unit 
commons "C" to electrical ground.

 