Fast-Stat 1000 Скачать руководство пользователя страница 3

 

Page 3 of 5

                        Specifications subject to change without notice                                                      

Nordic Technology Ltd            

www.fast-stat.com

 

 

P

u

rp

le

Yellow

Green

S

e

n

d

e

r

Purple

Green

Yellow

Purple

Thermostat Cable

Black

R

e

la

y

Sender

Receiver

R

e

la

y

Red

Yellow

Green

Outputs

To 24 volt 
power

Inputs

Green

Red

F

A

S

T

-S

T

A

T

1

0

0

0

Purple

Black

Thermostat
    Cable

C

Transformer

Fan

Heat

L1

N

Indoor Unit

Y

R

W

Thermostat

G

Air Conditioner

Y R

W G

Y

C

Step 1

This is how a typical single-stage heating and cooling system will be
wired before the powered thermostat is installed.

Step 2

Shut off power to the furnace. Remove the existing the thermostat. Using
the chart below, write down the colors of the wires connected to the R, W, G 
and Y terminals before disconnecting.

        R

       W

        G

        Y

        C

Purple

Step 3

Using the chart above, connect the thermostat wires to the R and W terminals 
of the powered thermostat. Connect the Sender green wire to the thermostat
G terminal. Connect the Sender yellow wire to the thermostat Y terminal.

At this point there will be two unused thermostat cable wires. Pick one wire
and connect it to the thermostat C terminal. Write down the color in the chart
above. Connect the remaining thermostat cable wire to the Sender purple wire.
Write down the color of the wire connected to the Sender purple wire in the 
above chart.

Thermostat
    Cable

C

Transformer

Fan

Heat

L1

N

Indoor Unit

Y
R

W

Thermostat

G

Air Conditioner

Y R

W G

Y

C

Step 4

At the indoor unit, remove the thermostat cable wires connected to the indoor unit 
G and Y terminals. Install the Receiver and connect it's red wire to R, the black to 
C, green to G and yellow to Y. Using the chart, connect the Receiver purple to the 
same wire that was used at the thermostat. The remaining thermostat cable is then 
connected to the indoor unit C. Check chart to make sure it is the right one.

C

Yellow

Step 5

Switch on the furnace power and test all thermostat functions in accordance 
with the thermostat manufacturer's instructions.

Tech Support:           1-800-775-4750
                                  Monday to Friday
                                  9:00 am - 5:00 pm PST

FAST-STAT Model 1000 - Installing a powered thermostat with a single transfomer & single-stage heating and cooling.

Internal Wiring

Nordic Technology Ltd                        www.fast-stat.com

 