7. RESIDUAL RISKS
7.1. Table of residual risks for the operator
Despite of the measures taken in the designing of the machine to guarantee a safe use of it, there might happen
reasonably predictable occurrences, whose risk was possible to reduce, but not to eliminate completely
.
RISK
DIRECT. 392
PRECAUTION
Injuries or crushing during loading and
unloading operations 1.6.4 4.1.1
1.6.4
4.1.1
Use security protective gloves and shoes
during loading and unloading operations
Abrasions and injuries caused by sharp edges and
parts of the cans to use
1.6.4
4.1.1
Use protective gloves during loading and
unloading operations
Liquid leakages from the cans
Clean carefully the area where the
operator works
7.2. Residual risks for technicians
RISK
DIRECT. 392
PRECAUTION
Danger of electrocution during maintenance caused
by electric charges of motor capacitors 115-230V
1.5.1
1.5.2
Use security shoes and gloves
.
7.3. Personal protection for user
If the equipment is used in a correct way, the machine, as produced in the factory, does not cause risks or
dangers for the user, who in any case have to wear individual protection (protective glasses, protective
shoes, protective gloves) especially during the loading and unloading of the cans.
7.4. General danger situations
There is not any particular hazardous situation (e.g. fire risk, loss/emission of dangerous substances) but in
any case it is necessary to have at hand a powder extinguisher for possible fire (electrical equipments).
Security components and devices
The machine is equipped with the following security devices:
•
An emergency push button
•
A door-locking device (solenoid)
Emergency push button
For safety reasons, all users should know the position and the way to use the red emergency push
button.
The emergency
RED
push button is assembled on the operator panel on the front part of the machine.
Pressing this button causes the immediate stop of the shaking cycle and the disconnection of the power
supply stopping the shaking motor. The normal functionalities of the equipment are restored by turning the
emergency push button clockwise. In case of emergency stop during the shaking cycle, the machine
functionalities will be restored after the reset procedure (just press Stop/Up).
Door lock (solenoid) and door-open micro-switch
These components are part of the same safety device (so micro-switch), which prevents shaking
cycle from starting if the door is open. During shaking cycle, the solenoid keep the door safely locked.