LUBRICATION & MAINTENANCE
LUBRICATION & MAINTENANCE
3PT Sprayer 973PT
Page 69
Rinse Tank
WARNING: Do not enter the tank at
any time.
Daily
At the end of the working day, clean the
system using this procedure:
1.
After the chemical solution has been
completely sprayed out through the
booms, add 20 gallons (75 liters)
clear water to the tank.
2.
Run the agitation pump for 5 minutes.
3.
Spray the rinse lightly over previously
sprayed crop.
4.
Repeat Steps 1 - 3 with 30 gallons of
water.
5.
Rinse the system again with clean
water.
6.
Clean the screen and nozzles.
7.
Drain the tank and let it dry.
To Change Chemicals or Remove Salt and
Amines Formations
Perform this cleaning cycle when changing
chemicals and/or annually.
1.
Follow the procedure for daily
cleaning.
2.
Remove all screens and nozzles and
wash them separately.
3.
Add 50 gallons (200 liters) of clean
water to the tank.
4.
Add 1/2 gallon (2 liters) of household
ammonia to the tank. (1-part
ammonia to 100 parts water).
5.
Run the agitation and rinse circuits
for 5 minutes.
6.
Spray half of the solution out of the
booms.
7.
Let the balance sit for a minimum of
8 hours; overnight is best.
8.
Run the agitation pump for 10
minutes.
9.
Spray solutions out of booms on the
appropriate crop.
10.
Rinse the system thoroughly with
clean water and flush out the booms.
11.
Drain the entire system and let it dry.
To Remove Esters of 2, 4-D and MCPA
Formations
Perform this cleaning cycle when changing
chemicals or annually:
1.
Complete the daily cleaning.
2.
Remove the nozzles and screens
and wash them separately.
3.
Add 50 gallons (200 liters) of clean
water to the- main tank.
4.
Add dishwasher detergent to the tank
(2 lbs. detergent to 50 gallons of
water (1 kg:300 L)).
5.
Run the agitation and rinse circuits
for 10 minutes.
6.
Spray the solution out of the booms
on appropriate crops and drain
thoroughly.
7.
Add 50 gallons (200 L) of clean water
to the tank.
8.
Add 1/2 gallon (2 L) of household
ammonia to the tank (1-part ammonia
to 100 parts water).
9.
Run the agitation pump for 10
minutes.
10.
Spray half of the solution out of the
booms.
11.
Let the balance sit for a minimum of
8 hours; overnight is best.
12.
Run the agitation and rinse circuits
for 10 minutes.
13.
Spray out of the booms on the
appropriate crop.
14.
Rinse the system thoroughly with
clean water and flush out the booms.
15.
Drain the entire system and let it dry.
Содержание 973PT
Страница 1: ...973PT 120 132 3PT SPRAYER OWNER S MANUAL...
Страница 2: ...820071 973PT 120 132 3PT Sprayer 2023 12 01...
Страница 33: ...SAFETY SAFETY 3PT Sprayer 973PT Page 33...
Страница 34: ...SAFETY SAFETY 3PT Sprayer 973PT Page 34 Main Frame...
Страница 35: ...SAFETY SAFETY 3PT Sprayer 973PT Page 35...
Страница 57: ...SPRAYER CALIBRATION SPRAYER CALIBRATION 3PT Sprayer 973PT Page 57 Table 3 Common conversions...
Страница 58: ...SPRAYER CALIBRATION SPRAYER CALIBRATION 3PT Sprayer 973PT Page 58 Table 4 Nozzle flow rates...
Страница 59: ...SPRAYER CALIBRATION SPRAYER CALIBRATION 3PT Sprayer 973PT Page 59 Table 5 Ground speed calibration...