Videotronic V788.G3: User
’s Manual
05 october 2016
2-5
Fig. 42
Fig. 43
Fig. 44
Fig. 45
4.0
CALIBRATION OF WHEEL BALANCER
4.1
How to calibrate the wheel balancer
G
NOTE
:
the following symptoms indicate need for calibration::
a) check calibration program fails.
b) constant low or high weight readings.
c) indicated point of unbalance constantly wrong
d) more than 2 spins required to balance wheels repeatedly
.
Switch on the wheel balancer.
Select
SET UP >
CALIBRATION >
SET/OK >
CALIBRATION > SET/OK.
Spin with no wheel on shaft (Fig. 43)
Close the wheel guard or press
<START>
.
At the end of the spin, put a wheel (Fig. 44) and
close the wheel guard or press
<START>
.
At the end of the spin, put the calibration weight
(Fig. 45) and close the wheel guard or press
<START>
.