Fasep 2000 srl
Rev. 1.6
Videotronic V548.G4: User’s Manual
15 April 2019
10
Fig. 46
4.2
How to control the calibration of wheel balancer and position weight (USER)
Switch on the wheel balancer.
Select
SET UP >
CALIBRATION >
SET/OK >
CHECK CALIBRATION
> SET/OK.
Put a wheel on the shaft and press
<START>
(Fig.46).
Put the calibration weight (Fig.47) and press
<SET/OK>
.
Close the wheel guard or press
<START>
.
At the end of the spin,
160-0
will show on the
video (tolerance allowed is ±10).
Put the weight at 6h o’clock: the weight
indicators of internal side must be both green.
If not, press
<6h>.
Put the weight at 6h o’clock and press
<SET
OK>
.
NOTA
technical calibration is only available for qualified personnel
Fig. 47
Fig. 48
Fig. 49