![FAS FNI MPL-302-105-M Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fas/fni-mpl-302-105-m/fni-mpl-302-105-m_user-manual_3506610009.webp)
4.5 Network port
Page 9 of
16
Port
2 x 10Base-/100Base-Tx
Port connection
M12
,
D-Code
IEEE 802.3 Compliant Cable Types
Shielded twisted pair, min. STP CAT 5/STP
CAT 5e
Ddata transfer rate
10/100 M bit/s
Maximum cable length
100m
Flow control
Half condition/full condition(IEEE 802.3-
PAUSE)
4.6 Function indicator
PT
Green
EtherNet/IP communication protocol
Yellow
ProfiNet communication protocol
Blue
EtherCat communication protocol
White
CC-Link IEField basic communication protocol
ECT Communication Protocol Module Status
LED
State
Function
US
Green
Power is OK
Red
Greater than 30V or less than 11V
Flashing red
less than 18V
UA
Green
Power is OK
Red
Greater than 30V or less than 11V
Flashing red
less than 18V
SF/MS/RU
N
Closure
No error, device initialization
Green light flashing
Pre-operational: The device is in a pre-operational state
2.5Hz
Safe Operation: The device is in safe operation
Green light flashes 1HZ
Running: The device is running
BF/NS/ER
R
Steady green
No errors, device EtherCAT communication is working
Closure
Invalid configuration
Red light flashes 2.5HZ
local error
Red light flashes 1HZ
Application watch timeout