5    Integrated 

5.1 

Module configuration 

5.1.1 Restore factory settings  

1. Power off the device, dial 900;

2. Power on the device and wait for 10 seconds;

3. Power off the device, dial the code to the state before setting

5.1.2 Node address configuration 

The node address is assigned by PLC: DIP address X100=4 X10=0 X1=0 

Manual assignment of node address: DIP address X100=4, node number X10=tens X1=ones 

For example: X100=4, X10=2, X1=5, the node number is 25. Note that after adjusting the dial code, it 
needs to be powered on again; 

Содержание FNI MPL-302-105-M

Страница 1: ...Page 1 of 16 FNI MPL 302 105 M IP 67 Module User Manual...

Страница 2: ...rity Notes 4 2 4 Resistance to Corrosive Substances 4 3 Getting Started Guide 3 1 Module overview 5 3 2 Mechanical connection 6 3 3 Electrical connection 6 4 Technical data 4 1 Size 8 4 2 Mechanical d...

Страница 3: ...can also be displayed numerically in parentheses 1 Step 1 2 Step 2 Number Decimal numbers are displayed without additional indicators eg 123 Hexadecimal numbers are displayed with an additional indica...

Страница 4: ...intended use The manufacturer s warranty coverage and limited liability statement do not cover damage caused by Unauthorized tampering Improper use Owner operator s obligations This device is an EMC...

Страница 5: ...ndicator 3 Network port 2 4 Power outlet 5 DIP switch 6 Port 1 8 Port 5 9 Port 7 10 Port 6 11 Port 4 12 Port 2 13 Port Status Indicators 15 Port Identification Board 16 Power input port 17 Module indi...

Страница 6: ...Us 0V 4 Ua 24V FE Functional ground FE Notes 1 If possible supply sensor module power and actuator power separately Total current 9A The total current of all modules is 9A even when daisy chaining the...

Страница 7: ...t guidelines of EN61131 2 Type 2 2 The maximum output current of pins 2 and 4 is 2A The total current of the module is less than 9A 3 Unused I O port sockets must be covered with end caps to meet IP67...

Страница 8: ...interface L Code Male and Female Input port output port M12 A Code 8 female Size W H D 65mm 222mm 25 8mm Installation type 2 Through Hole Mounting Ground Bus Accessories M4 weight About 670g 4 3 Oper...

Страница 9: ...on protocol ECT Communication Protocol Module Status LED State Function US Green Power is OK Red Greater than 30V or less than 11V Flashing red less than 18V UA Green Power is OK Red Greater than 30V...

Страница 10: ...Page 10 of 16 Red light double flash Application monitoring timeout...

Страница 11: ...current 2 Closure Port configured as output short circuit between Pin1 and 3 2 Yellow The status of Pin2 input or output is 0 2 Rred The state of Pin2 input or output is 1 2 Flashing red Port configur...

Страница 12: ...wer off the device dial the code to the state before setting 5 1 2 Node address configuration The node address is assigned by PLC DIP address X100 4 X10 0 X1 0 Manual assignment of node address DIP ad...

Страница 13: ...0 PIN4 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 1 PIN2 input Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 2 PIN4 short circuit status Port7 Port6 Port5 Port4 Port3 Port2 Port1 Port0 3...

Страница 14: ...NX1P2 Sysmac Studio Integrated ECT 1 Install the ESI file double click EtherCAT in the configuration and settings right click the master device select Show ESI library and select the ESI file in the...

Страница 15: ...ight find the module model icon and double click to add it to the network 3 The PLC goes to online mode right click the master device and write the node address ofthe slave device 4 Variable mapping S...

Страница 16: ...dix 6 1 Included materials 6 2 Order code FNI MPL contains the following components I O block 4 blind plugsM12 Ground bus Thread M4x6 20 tags 6 3 Ordering Information Product order code Order code FNI...

Отзывы: