Diesel engine Series 15W / 18W
Structure and function
2008-12-09
35
4.2.4 Dangers and cause of failure
Dangers
Cause of failure
Battery terminals incorrectly
connected
Damage to the charging circuit
Defective battery or complete
discharge
Destruction of the alternator
regulator
Disconnection of the battery
when the engine is running
Immediate destruction of the
alternator regulator
External start with jump leads
for defective or completely
discharged battery
Destruction of the alternator
regulator
Manual starting with
disconnected battery
Destruction of the alternator
regulator
Interruption of the earth
connection of the alternator
regulator to the engine
Destruction of the alternator
regulator
Welding work
WARNING!
Material damage due to welding work on the
machine!
Welding work on the machine can cause high
material damage.
Therefore:
– always disconnect the negative pole of the
battery in advance.
– disconnect the plug connection to the
alternator regulator.