10
RS232 CODES
Following the header, a comma is used to delimit the
header from the command. All the commands with
their descriptions are listed below. All the text strings
are terminated with a carriage return (0x0d or 13).
Maximum command string length is 250 characters.
The header and command are not case sensitive
.
OPERATION COMMANDS
(Used for day-to-day operation)
COMMAND
OPTIONS OR RANGE
DESCRIPTION
A#
(0-2) 0=4x3,1=Letterbox, 2=Anamorphic
Input Aspect Ratio – for all sources
B#
(0-170) 128 default
Brightness
C#
(0-155) 110 default
Contrast
D#
(0-13) 8 default
Detail
DVI
DVI Input
EXT
Pass-through Input
FST
Report Current System Status
HELP
Displays full list of commands for this unit
K#
(0-220) 128 default
Color
OFF
Power OFF
ON
Power ON
P#
(0-8) [1-8=User, 0=Factory]
Recall Profiles
PM#
(0-1) [0=Normal1=Bypass]
Advanced Color System
PY
PassThru Transcoded Input
R
RGB input
ST
Report Current Status
T#
(0-255) 128 default
Tint
TP#
0=Off
1=100% Color Bars
2=Reverse Color Bars
3=10-step Grayscale
4=Luma Ramp
5=Cb Ramp
6=Cr Ramp
7=Green
8=Red
9=Blue
10=Convergence
11=Active Boarder
12=Multiburst
13=100% Window
14=PLUGE Test Pattern Selection
TPHELP
Display Test Pattern Help
V
Video input
X
YCrCb input
Y
S-Video input
SETUP COMMANDS
(Normally not controlled by RS232)
COMMAND
OPTIONS OR RANGE
DESCRIPTION
BB# (0-192)
Bottom
Blanking
BL#
(0-252)
Border Level – black to white
BLT#
(0-255)
LCD Backlite Timer on front panel
BLV#
0=0IRE (DEFAULT) , 1 = 7.5 IRE
BLACK LEVEL
CR#
0=0-255, 1=16-235
DVI INPUT LEVEL
CS#
1=On 0=OFF
Composite Sync – for RGB output
DVD
DVI Input Disabled
DHS#
0=NORMAL, 1=WIDE
DVI INPUT H SYNC