- 46 -
VENT PIPE INSTALLATION
• Adjustable lengths
Adjustable lengths are available to allow for installation where fixed-length sections do not
produce the desired dimensions. Also adjustable lengths may be used to compensate for
linear thermal expansion/contract between two fixed points.
As shown in Table1, 2 types of adjustable lengths are available according to the limits in which
its effective length can be made longer and shorter.
• Elbows
45º and 90º elbow are available for changing the direction of the vent system.
The flexible section of each can be bent by hand for making small angle adjustment.
Do not bend repeatedly or extremely, because it may cause vent gas leaks.
• Drain tee
Connect the drain tee directly on to the appliance flue outlet as shown in Fig. 4-4, page 45.
Attach one end of a drain hose to the drain tee outlet, and the other end to a condensate drain
so that any steam or condensed water will be handled properly.
The drain hose must be suitable for use with acidic effluent. Follow the appliance manufacturer's
instructions, and all local and national codes for draining the condensate and acidic effluent.
Caution
: Periodically check the terminal end to ensure it is not blocked or obstructed.
• Support
Support the vent system every 5' (1.5m).
1) Secure the support to solid material using the screws provided with the support.
2) Loosen the nuts of the cylinder.
After inserting pipes, fasten the loosened nuts.
Use the pairs of nuts and bolts provided with the support.
Содержание MWH-180
Страница 60: ... 58 WIRING DIAGRAM ...
Страница 61: ... 59 WIRING DIAGRAM ...