background image

17. OPERATION IN TRANSITION PERIODS 
During transition periods when the external temperatures are higher, or if there is a sudden increase 
of temperature it can happen that the combustion gases inside the flue cannot be completely sucked 
out. 
The exhaust gases do not come out completely (intense smell of gas). In this case, shake the grating 
more frequently and increase the air for the combustion. Then, load a reduced quantity of fuel in 
order to permit a rapid burning and the stabilization of the draft. 
 Then, check whether  all openings for the cleaning and the connections to the stack are air-tight. In 
case of doubt, do not operate the stove. 
 
 
18. CLEANING 
Let the installation of your stove, the connection to chimney and the ventilation be checked by your 
chimney  sweeper.  For  the  cleaning  of  enameled  surfaces  use  soap  water  or  non-aggressive  and 
materials who are not chemically abrasive. Clean the glass with a detergent and water, and the glass 
has to be dry prior using the stove. Do not use abrasive matters that can damage the glass surface. 
 
 
IMPORTANT:  It  is  possible  to  use  exclusively  spare  parts  clearly  authorized  and  offered  by 
the manufacturer. In case of need please apply to your dealer! 
 
THE  APPLIANCE  CAN  NOT  BE  MODIFIED  WITHOUT  PRODUCER’S  CONSENT! 
Clean the stove, pipes, and the flue regularly. 
 
 
 
18.1 CLEANING OF THE FLUE 
A  correct  lighting,  the  burning  of  a  proper  fuel,  the  loading  of  the  suggested  quantity  of  fuel,  the 
right  adjustments  of  the  secondary  air  control,  the  sufficient  draught  of  the  chimney  and  the 
presence of air for the combustion, are essential for the good operation of the appliance. 
 The appliance must be completely cleaned at least once a year or every time it is needed (in case of 
bad working and low yield).The cleaning must be carried out exclusively when the stove is cold. 
 
This  operation  should  be  carried  out  by  a  chimney  sweeper  who  can  simultaneously  perform  an 
audit of the flue (checking possible deposits). During the  cleaning, it is necessary to remove  from 
the appliance the ash drawer and the smokes pipes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LAVA

Страница 1: ...Concern FARMAKOM M B Šabac Industrijski kombinat GUČA AD Guča Installation Manual Model LAVA ...

Страница 2: ... FOR YOUR SAFETY CONTACT LOCAL BUILDING OR FIRE OFFICIAL ABOUT PERMITS RESTRICTIONS AND INSTALLATION REQUIRE MENTS FOR YOUR AREA PLEASE CHECK WITH YOUR INSURANCE BEFORE USING IN YOUR HOME USE PROFESSIONAL INSTALLER CAUTION Hot while in operation do not touch Contact may cause skin burns Keep children and clothing away Keep furnishing and other combustible materials a considerable distance away fro...

Страница 3: ...d like to thank you for having chosen us and your trust in us will not be failed You will be satisfied with your choice as our stove is in the leading category of the similar products due to its features and design Yours sincerely GUČA ...

Страница 4: ... exhaust gasses in C wood 283 3 Size of hearth opening in mm W x H 340x286 13 4 x11 25 Hearth body size W x H x P 450x230 x 334 17 7 x9 x13 15 Stove height in mm 946 35 43 Stove width in mm 540 21 25 Stove depth with handles in mm 493 19 4 Weight in kg 155 341lbs Outer smoke output in mm 900 37 24 Accessory glove Hearth door is closed automatically there is the system for automatic door closing wi...

Страница 5: ...Flue connector pipe should be 6 diameter minimum single wall 24 msg black or 25 msg blued steel Listed to UL 103 Type HT and evaluated to CAN ULC S629 M87 9 Do Not overfire The special paint used on stove may give off some smoke and an odor while they are curing during first few fires Open windows and doors as needed to clear smoke and odor Overfiring may cause some damage to the stove 10 Use only...

Страница 6: ... AIR DISTRIBUTUIN OR DUCT SYSTEM 6 Slope any horizontal stove pipe upward toward the chimney at least 1 4 inch for each foot of horizontal run 7 You must have at least 18 of clearance between any horizontal pipe and ceiling 8 The stove pipe must NOT extend to far into the chimney flue 9 It is recommended that no more than two 2 90 degree bends be used in the stove pipe in stallation 10 Connect to ...

Страница 7: ... pass through attic or roof space closet or similar concealed space or a floor or ceiling When passage through a wall or partition of combustible is desired the installation shall con form to CAN CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment ...

Страница 8: ......

Страница 9: ... member Appliance must be positioned so that no combustibles are within or can swing within e g drapes doors 48 of the front of the appliance CLEARANCE TO COMBUSTIBLES DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET CEILING OF ENCLOSURE TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT PARALLEL CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR Lava Lava SIDEWALL A SIDEWALL TO FLUE B BACKW...

Страница 10: ...diately if stove pipe is rusting or leaking smoke 7 Inspect the stove pipes connectors and chimney twice monthly during the heating season and clean if necessary CAUTION SLOW BURNING FIRES AND EXTENDED USE MAY CAUSE EXCES SIVE CREOSOTE BUILDUP IGNITION OF CREOSOTE SOOT OR OVERFIRING MAY CAUSE CHIMNEY FIRE CHIMNEY FIRES BURN EXTREMELY HOT AND MAY IGNITE SURROUNDING MATERIALS IN CASE OF CHIMNEY FIRE...

Страница 11: ... TIME EXCEPT WHILE TENDING THE FIRE ALWAYS OPEN DRAFT CONTROLER BEFORE OPENING THE FEED DOOR ABOUT DRAFT The principle of draft is that warm air rises Your chimney provides draft which sucks the smoke up the chimney The stove does NOT PUSH out the smoke Your stove has been design and approved for use under normal conditions Unacceptable smoking usually indicates poor draft in your chimney Normal o...

Страница 12: ...wall is not subject to high temperatures The spacer used must be non combustible Another method to achieve the same type of protection is using brick or masonry with 1 air space between the brick or masonry and the wall When reducing distances please check local codes and consult with professional installer Reduced installation must comply with NFPA 211 or CAN CSA B365 WARNING Do not place stove t...

Страница 13: ...the back side picture 2 picture 1 picture 2 The cast iron parts are protected by heat resistant paint and during the first few exploitations smoke and smells which are products of paint stabilization occur The room has to be properly ventilated The stove is to work with the doors closed Open the door only in the case of fuel addition Open the door slowly in order to equalize the pressure Abrupt do...

Страница 14: ...ing the stove installation A badly installed stove can cause serious accidents chimney fires burning of insulating materials etc 3 3 Lighting the stove for the first time The first time the stove is lit there will be smoke and odor given off due to the drying of the protective color That is normal because the color stabilizes on temperatures over 350 C THE ROOM MUST BE PROPERLY VENTILATED Before t...

Страница 15: ...hrough the flue If the draught is greater than 15Pa the elements for draught reduction should be installed The signs of a bad draught are dirty glass boiling handle smoke coming out into the room 4 1 General characteristics Add chimney sections according to the manufacturer s installation instructions The chimney must extend at least 3 feet above its point of contact with the roof and at least 2 f...

Страница 16: ... flue Every time you notice the draught is becoming difficult you should clean the stove the tubes and the flue The removal of soot and carbon residues must be carried out to the highest standards using appropriate means Cleaning should be performed when the stove is cold The junction pipe for the connection to the chimney must be shortest possible and the junction points of the single pipes must ...

Страница 17: ...oducts such as acetic acid alcohol methyl alcohol and tars which contribute to the formation of incrustations which are detrimental for the efficiency of your stove Fresh cut wood is useless as a fuel Actually a considerable part of the energy produced is only used to evaporate the water which is up to 75 in young wood without bark To obtain dry wood 15 20 humidity you must cut the weak wood in wi...

Страница 18: ...struct the circulation of primary air and slowly suffocate the fire When cleaning the outside surfaces of the stove avoid abrasive products which would damage the protective paint Do not use chemicals that contain diluent because the cast parts are protected by heat resistant paint Panoramic door glass should be cleaned with normal detergent and exclusively after getting cold After cleaning rinse ...

Страница 19: ... be well sealed 9 2 Difficulty in lighting the fire Open the primary air and the smoke register Use very dry wood Air the room in order to have a great quantity of oxygen The flue must be appropriated to the appliance used 9 3 Smoke comes out Check if the primary air register is opened Check if the entrance of the chimney presents leaks Check if the ash or other residuals have obstructed the drain...

Страница 20: ...e the heat is radiated into the environment The chimney stove is equipped with registers of primary and secondary air by which the combustion air is adjusted The stove can be attached from the back or through the heating plate 10 2 PRIMARY air control With the regulator on the stove door the passage of air through the ash drawer and the grate in the fuel direction is adjusted The primary air is ne...

Страница 21: ...ction for the reception of the exhaust pipe Before installation verify if your floor can support the weight of the stove and in case that the bearing capacity of the floor is insufficient perform measures for increasing the capacity The manufacturer is not responsible in case of modification of the product and for the use of not original spare parts 12 FIRE SAFETY In the installation of the stove ...

Страница 22: ... intervention of FIRE BRIGADE DO NOT EXTINGUISH FIRE USING WATER JETS When the fire has been extinguished let the flue be checked by an expert to find possible cracks and permeable points 13 AIR ENTRANCE INTO THE INSTALLATION PLACE DURING COMBUSTION As the stoves take their combustion air from the installation place it is essential that a sufficient quantity of air is introduced in the installatio...

Страница 23: ...t be burnt remainders of coal scraps of bark and panels humid wood or treated with varnishes plastic materials materials of organic origin in this case the warranty on the equipment expires Variety Kg m3 Kwh Kg moistness 20 Beech 750 4 0 Oak 900 4 2 Elm 640 4 1 Poplar 470 4 1 Larch 660 4 4 Spruce 450 4 5 Scots pine 550 4 4 wood not suitable for burning Paper and carton must be used only for igniti...

Страница 24: ...ructions manual 3 Repeat this operation for at least 4 5 or more times according to your possibilities 4 Then load more and more fuel following in any case the provisions contained in the installation booklet concerning maximum load and keep the fire on for a longer time period 5 During the first starts no object should be leaned on the appliance or touch enameled surfaces 6 Once the break in has ...

Страница 25: ... the combustion passes through the regulator of secondary air Never overload the stove compare the technical table max quantity of loadable fuel The warranty does not cover the damages due to overheating of the equipment You should always use the stove with the door closed in order to avoid damages due to overheating The adjustment of the regulators is as follows Fuel Secondary air A1 Primary air ...

Страница 26: ...and water and the glass has to be dry prior using the stove Do not use abrasive matters that can damage the glass surface IMPORTANT It is possible to use exclusively spare parts clearly authorized and offered by the manufacturer In case of need please apply to your dealer THE APPLIANCE CAN NOT BE MODIFIED WITHOUT PRODUCER S CONSENT Clean the stove pipes and the flue regularly 18 1 CLEANING OF THE ...

Страница 27: ...tured for temperatures up to 700 C it should not be subjected to thermal shocks The break can be caused by mechanic shocks hits or violent closure of the door etc Therefore its replacement is not included in the warranty 18 3 CLEANING OF THE ASH DRAWER The stove has a hearth grate and an ash drawer for the collection of ashes We suggest you to empty periodically the ash drawer and to avoid filling...

Страница 28: ...neutral Vaseline We hope that you have read this instruction thoroughly and that you will not have any problems while using the stove In case of any complaints call the local vendor or the manufacturer 19 Recommendations for environmental protection Product The device is made of recycable material Before storing to waste observe the valid laws on protection of environment Use only the recommended ...

Страница 29: ......

Страница 30: ... P 064 1 37 P 027 1 14 P 063 1 36 P 080 1 13 P 062 1 35 P 079 2 12 P 061 2 34 P 083 1 11 P 060 1 33 P 078 2 10 P 059 1 32 P 077 1 9 P 058 1 31 P 076 2 8 P 057 1 30 P 075 1 7 P 056 1 29 P 074 1 6 P 055 2 28 P 073 1 5 P 054 1 27 P 025 4 4 P 053 1 26 P 072 1 3 P 052 2 25 P 071 1 2 P 051 1 24 P 071 1 1 P 050 3 23 P 069 2 position mark units position mark units ...

Страница 31: ... mainte nance accident alterations abuse or neglect This limited warranty does not cover any scratches dents corrosion or discoloring caused by excessive heat cleaning chemicals nor chipping on porcelain enamel parts nor any venting components used in the installation Installation must be done in accordance with installation instructions included with product and all local and national building an...

Отзывы: