2010
HID
Global
Corporation
All
rights
reserved
DTC1000/DTC4000
Card Printer/Encoder User Guide (L001398, Revision 1.2)
68
Using the Magnetic Encoding Tab – ISO Standards
Window TAB
Procedure
Procedure (continued)
If you select
JIS II
Encoding
, specific
standards are used.
This selection disables all the
Magnetic Track Options tabs.
It also disables the Coercivity
dropdown function and
Shift
Data Left
checkbox option.
The default Coercivity is 600 Oe.
Select the
Coercivity
option (Oersted) that
matches the card type.
•
High Coercivity 4000
Oersted
•
Fargo’s High Coercivity
UltraCard IIIs are 2750
Oersted
•
Medium Coercivity=600
Oersted
•
Low Coercivity = 300
Oersted
Select this option to shift
the recorded magnetic
data to the left-hand
side of the card's
Magnetic Stripe.
This is useful in situations that
require cards to be readable
with insert type readers.
Select the
Magnetic
Track Selection
option
to specify which track is
to be configured through
the Magnetic Track
Options.
This applies if the application
being used
requires
customization of the standard
ISO encoding process.