USE AND MAINTENANCE MANUAL - SECTION 6
AERIAL PLATFORM ELEVAH 65-80 MOVE - Rev. 07_2019
Page 6-1
SECTION 6.
DAILY INSPECTION
Start the full inspection from point (a), as set out in the following list. Proceed around the machine
checking all listed conditions in sequence.
ATTENTION
TO PREVENT ANY INJURIES, ENSURE THAT THE MACHINE POWER SUPPLY IS SWITCHED
OFF DURING THE “FULL INSPECTION.”
DO NOT USE THE MACHINE BEFORE REPAIRING ALL FAULTS.
DO NOT FAIL TO CARRY OUT A VISUAL INSPECTION OF THE LOWER PART OF THE BASE
FRAME. ENSURE THE AREA IS CLEAR OF OBJECTS OR DEBRIS THAT MIGHT CAUSE
SERIOUS DAMAGE TO THE MACHINE.
NOTE FOR INSPECTION: besides complying with the above criteria, ensure for each component
that all parts are in place, securely fixed and not loose, and that there is no visible damage, leaks or
signs of excessive wear.
a)
Drive wheels/free wheels and swivel wheels
Check there is no debris attached to the wheels or around them;
b)
Base frame
Ensure there are no loose wires or cables hanging underneath the base, check for any dents,
breaks or cracks on the profiles;
c)
Manual descent control valve
– See note pertaining to functional check;
d)
Motor/pump/tank unit
No conspicuous hydraulic leak, hydraulic oil filling level at the "full" line;
e)
Batteries
Charge them as required;
f)
Cage assembly and entrance doors
Proper locking of the cage and entrance doors operating correctly;
g)
Control console in the cage
Controls secured, legible signs, emergency stop switch in the reset position for operation and
legible control signs;
h)
Ground control station
Ascent/descent control switch operable, signs securely fastened and legible, operable
emergency stop switch;
i)
Extensible structure unit
Structure profiles, sliding inserts, chains, belts, sequential activation cables, pulleys able to turn
freely;
ATTENTION
DO NOT USE THE MACHINE BEFORE REPAIRING ALL DISCOVERED FAULTS /
MALFUNCTIONS
Содержание ELEVAH 65 MOVE