General  Information 

1. General Information

This  digital  multimeter  1s  designed  and  manufactured  in 

compliance  with  IEC-61010  safety  requirements  on  electronic 

measuring  instruments  and  hand-held  digital  multi-meters.  It  is 

compliant with IEC-61010 requirements pertaining to 600V  CAT IV, 

1000V  CAT.ill and requirements on pollution degree 2.  Please read 

carefully  this  Operation  Manual  and  pay  attention  to  safety 

guidelines before operating this meter. 

1.1 Safety information 

1.1.1 Safety instructions 

* Before operating this meter, the operator must  observe all standard

safety procedures in the two respects below:

A. Safety procedures against electric shock

B. Safety procedures against unintended use

*

To  ensure  your  personal  safety,  prease  use  the  test  lead  that

accompanies the meter. Before operating this meter, ensure that the

test lead is flawless.

1.1.2 Safety considerations 

* When  the  meter  is  used  in  the  vicinity  of  the  equipment  that

produces strong electromagnetic interferences,  the reading on the

meter will grow unstable and even produce serious errors.

*

Don't operate the meter or pen-shaped meter whose appearance is

damaged.

* The safety function of the meter will become null if the meter is not

properly operated.

*

The  meter must be operated  with great care when working in  the

vicinity of an exposed conductor or bus line.

*

The  meter  is  prohibited  from  being  used  in  the  vicinity  of  any

explosive gas, vapor or dust.

* The  measurement must be made with  correct  input terminals and

functions and within the allowable measuring range.

* To prevent the meter from being damaged, the value to be input shall

not exceed the extremes allowed by each measuring range.

* When  the  meter  has  already  been  connected  to  the  line  being

, '. 

--

Содержание FDM18A

Страница 1: ...USERS MANUAL 1i AMADIGI TRUE RMS MULTIMETER t afili DmfJ m m fflo1 8 100 10 ill LI LI LI B MkQHz amAVF C F...

Страница 2: ...5 Physical appearance 5 2 2 Description of the symbols on the display unit 6 2 3 Description of functional keys 7 2 4 Description of input socket 8 2 5 Accessories 8 3 Operational guidelines 9 3 1 No...

Страница 3: ...ameters 15 4 1 Overall parameters 15 4 2 Precision indicator 16 4 2 1 DC voltage 16 4 2 2 AC voltage 17 4 2 3 Frequency 17 4 2 4 Electric resistance 17 4 2 5 Diode 18 4 2 6 Beeper continuity 18 4 2 7...

Страница 4: ...accompanies the meter Before operating this meter ensure that the test lead is flawless 1 1 2 Safety considerations When the meter is used in the vicinity of the equipment that produces strong electro...

Страница 5: ...all high voltage capacitors within the circuit to be measured The eiectric resistance measurement or continuity test cannot be carried out in any live electrical circuit Before the current measuremen...

Страница 6: ...European Union Directive High voltage warning CAT ID over voltage protection 1000V CAT IV over voltage protection 600V 1 1 4 Maintenance practices for safety The operator must first pull out the test...

Страница 7: ...an sustain the maximum input voltage of 1000V DC or 750V AC at the moment of voltage measurement The meter can sustain the maximum AC voltage of 600V or equivalent voltage valid value when the tests o...

Страница 8: ...li c J CJ c J A 1000YCATlll I A eooYCA T IV_ ___ 1 QA IIAX10A IIAX o l ff FUSED 7S N VQHz 10 1000V OM A IIAX600mA t FUSED Physical appearance Non contact voltage detection area Non contact voltage ind...

Страница 9: ...jury as a result of incorrect reading promptly replace the battery when the battery under voltage indicator appears C Auto power off indicator High voltage warning Negative input polarity indicator AC...

Страница 10: ...y KHz lx103 Hz MHz lx106 Hz or 1000 KHz Farad the unit of capacitance Millifarad lxl0 3 or 0 001 farad Microfarad lxl0 6 or 0 000001 farad nF lxl0 9 or 0 000000001 farad 2 3 Description of functional...

Страница 11: ...ription of input socket input Description socket All public input terminals to be measured are COM connected to test leads in black or the public output plugs of exclusive multi function test sockets...

Страница 12: ...ccess measurement results even if he is in a darker place The backlight function can be enabled or disabled by the steps below 1 Long press key for more than 2 seconds to enable backlight and illumina...

Страница 13: ...and V input socket respectively 3 Use another two ends of the test lead to measure the voltage of the circuit to be measured In parallel connection with the circuit to be measured 4 Read the measured...

Страница 14: ...ric resistance of the circuit to be measured 4 Read the measured electric resistance value on LCD screen Notes The measured value of the electric resistance of the circuit differs a bit from the rated...

Страница 15: ...as voltage reading depend on the variation in electric resistance of other channels between two pen shaped meters 3 2 4 Beep continuity test To avoid the meter or the measured equipment from damage do...

Страница 16: ...Use another two ends of the test lead to measure the capacitance of the capacitor to be measured and capture the measured value on LCD screen Notes The measurement of a large capacitance requires a gi...

Страница 17: ...g ranges as follows 60 A 600 A 6mA 60 00mA 600 0mA and 10 00A and AC current measuring ranges 60 A 600 A 6mA 60 0mA 600 0mA and 10 00A Measurement of current 1 Turn the rotary switch to the appropriat...

Страница 18: ...gn insulation thickness and type 2 When the voltage is input into the meter s input terminal the voltage sensor LED may be on as a result of induced voltage 3 External sources of interference like fla...

Страница 19: ...nge indication the LCD screen will display OL Battery Low indication F I will appear when the battery s voltage is below the normal working voltage Input polarity indication will automatically appear...

Страница 20: ...suring range 9 999Hz 99 99Hz 999 9Hz 9 999KHz 99 99KHz 999 9KHz 9 999MHz Resolution Accuracy 0 001Hz O OlHz O lHz 0 001 KHz 1 Reading 3 digits 0 01 KHz 0 1 KHz 0 001MHz Input voltage range 200mV 10V a...

Страница 21: ...he diode s voltage drop Overload protection 600V DC AC 4 2 6 B eeper continuity Functi Measur Resolution ans 1ng range 01 Goon O ln Description When the built in beeper sounds and the accompanying red...

Страница 22: ...ding 3 digits 5 0 Readinq 3 diaits Accuracy 0 8 Reading 3 digits 1 2 Readinq 3 diqits Overload protection protective tube for mA measuring range FF600mA 2 SOV protective tube for lOA measuring range F...

Страница 23: ...ement shall not be over 10 seconds The current measurement shall be carried out 1 minute after the completion of previous measurement Frequency response 40Hz lkHz True RMS 4 2 10 Ti t empera ure Measu...

Страница 24: ...ent the socket vulnerable to dampness from pollution 5 2 Battery fuse replacement To avoid any electric shock or personal injury as a result of incorrect reading replace batteries once the symbol 1 I...

Страница 25: ...6 Make replacements with new 4x 1 5 V AA batteries or new protective tubes 7 Remount the battery cover and fix a bolt 22 _ r...

Страница 26: ...EMC LVD YO 1 04 0154...

Отзывы: