DADI DI FISSAGGIO
FAR Rubinetterie S.p.A. - www.far.eu
SERVOCOMANDO “SMALL”
ISTRUZIONI PER L’USO
ART.3001 20 230 V
ART.3001 40 230 V
ART.3002 20 24 V
ART.3002 40 24 V
ART.3005 20 230 V
ART.3005 40 230 V
ART.3006 20 24 V
ART.3006 40 24 V
ART.3007 8 230 V
ART.3008 8 24 V
ARTICOLO
TENSIONE
FREQUENZA
POTENZA
ASSORBITA
ANGOLO DI
ROTAZIONE
TEMPO DI
ROTAZIONE
COPPIA
MOTRICE
TEMPERATURA
D’IMPIEGO
GRADO DI
PROTEZIONE
COLORE
3001 20
230 V-50Hz
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GIALLO
3001 40
230 V-50Hz
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GIALLO
3002 20
24 V-50Hz
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GIALLO
3002 40
24 V-50Hz
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GIALLO
3005 20
230 V-50Hz
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
VERDE
3005 40
230 V-50Hz
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
VERDE
3006 20
24 V-50Hz
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
VERDE
3006 40
24 V-50Hz
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
VERDE
3007 8
230 V-50Hz
6 VA
90°
8 S
6 Nm
-10° + 50°C
IP54
GRIGIO
3008 8
24 V-50Hz
6 VA
90°
8 S
6 Nm
-10° + 50°C
IP54
GRIGIO
Adatto per l’utilizzo in ambiente con forte polluzione
azione di tipo 1 C.D
1. DESCRIZIONE DEL SERVOCOMANDO
Il servocomando, costituito da un motoriduttore, permette la manovra di
una valvola di zona in modo completamente automatico, prelevando il
segnale per il suo azionamento da un termostato ambiente con regolazione
ON-OFF di tipo tradizionale, un cronotermostato o da un qualsiasi contatto
elettrico di apertura/chiusura. Tramite un indicatore è possibile conoscere
in che posizione si trova la valvola.
Per l’installazione controllare che il servocomando sia in posizione di
“APERTO” verificando che l’indicatore di posizione sia orientato nel senso
di moto del fluido. Predisporre la valvola in posizione di “APERTO” ossia
che il taglio a cacciavite sia orientato come il perno del servocomando.
Inserire i prigionieri negli appositi fori sulla flangia della valvola e bloccare
con i dadi forniti in dotazione. Il servocomando si può installare su tutte le
valvole di zona FAR. Non è adatto all’utilizzo in atmosfera esplosiva.
2. UTILIZZO DELLO SBLOCCO MANUALE
Lo sblocco manuale può essere utilizzato per:
- Interrompere il flusso d’acqua nel caso di interventi
straordinari sull’ impianto
- Posizionare la valvola una volta installato il motore
- Mancanza di corrente elettrica
Per portare in apertura o in chiusura il motore
manualmente, tenere premuto il tasto di colore giallo
e contemporaneamente ruotare di 90° in senso
antiorario l’indicatore di posizione. Il ripristino del
funzionamento normale avviene automaticamente.
3. COLLEGAMENTI ELETTRICI
Prima di collegare elettricamente il servocomando accertarsi che il modello prescelto sia compatibile con la tensione di rete disponibile.
Tutti i collegamenti devono essere effettuati da personale specializzato rispettando lo schema elettrico (riportato anche sul servocomando)
ed accertandosi che la linea elettrica non sia sotto tensione. Allacciamenti errati possono provocare danni sia alle persone sia al
servocomando.Tutte le versioni sono predisposte con microinterruttore ausiliario supplementare, ossia con contatti di scambio senza
tensione, a disposizione dell’utente per segnali a bassa tensione (max 230 V) e/o per alimentare utenze a basso assorbimento (max 2A).
COLLEGAMENTO A 3 FILI: COMANDO CON TERMOSTATO AMBIENTE
COLLEGAMENTO A 5 FILI: COMANDO CON TERMOSTATO AMBIENTE E ACCENSIONE POMPA
Per comandare l’apertura e la chiusura della valvola di zona per
mezzo del servocomando, basta collegare il cavo di colore blu al
neutro dell’alimentazione, il cavo di colore marrone alla fase ed il cavo
di colore nero al termostato ambiente. Con presenza di fase sul cavo
nero la valvola va in apertura.
Per il corretto funzionamento del servocomando è importante che il
cavo marrone sia sempre sottotensione.
La presenza del microinterruttore ausiliario (contatto pulito) interno
collegato ai cavi grigio e bianco, essendo indipendente dal circuito
del servocomando, permette l’allacciamento di più servocomandi in
parallelo per governare un’unica apparecchiatura come ad esempio la
pompa o la caldaia. Nel caso si debba comandare l’avviamento della
pompa già presente in caldaia, basta collegare i cavi di colore grigio
e bianco ai due morsetti predisposti (sulla caldaia) per l’allacciamento
al termostato.
1
2
3
N
5
6
7
MORSETTIERA INTERNA
GRIGIO
BIANCO
BLU
MARRONE
NERO
COLLEGAMENTO
DESCRIZIONE
COMUNE DEL MICROINT.
COLLEGATO AL COMUNE
MICROINTERRUTTORE AUSILIARIO
N.A. DEL MICROINT.
COLLEGATO AL NORMALMENTE APERTO
DEL MICROINTERRUTTORE AUSILIARIO
SPIE DI SEGNALAZIONE
CON VALVOLA APERTA
PRESENZA DI FASE SUL MORSETTO
NEUTRO
COLLEGAMENTO AL NEUTRO
FASE
COLLEGAMENTO ALLA FASE
APRE
CON FASE SUL NERO LA VALVOLA SI APRE
CHIUDE
IN ASSENZA DI FASE SUL NERO LA
VALVOLA SI CHIUDE
SPIE DI SEGNALAZIONE
CON VALVOLA CHIUSA PRESENZA DI
FASE SUL MORSETTO
N°
COLORE
1
GRIGIO
2
BIANCO
3
-
N
BLU
5
MARRONE
6
NERO
7
-
DIRETTIVA 2002/96/CE SUI RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE
La direttiva comunitaria 2002/96/CE sui RAEE (rifiuti di apparecchiature elettriche ed elettroniche) prevede che sia vietato
smaltire qualsiasi tipo di RAEE come rifiuto solido urbano ma debba essere obbligatoriamente gestito separatamente.
Per il corretto smaltimento dei RAEE occorre rivolgersi alle autorità locali che informeranno sulle modalità e procedure
da seguire, nonchè sul luogo e sugli orari per i quali dovrà essere conferito il rifiuto.
DICHIARAZIONE DI CONFORMITA’
La FAR Rubinetterie dichiara sotto la propria responsabilità che i servomotori sono conformi alle direttive comunitarie:
2004/108/CE e 2006/95/CE.
4. ASSISTENZA TECNICA
Per qualunque tipo di problema evitare di intervenire direttamente e contattare FAR Rubinetterie S.p.A . via Morena, 20 28024 GOZZANO
(NO) Tel. 0322/ 94722 - 956450 - FAX 0322-955332
Il servocomando è a doppio isolamento per cui non necessita della messa a terra.
NON RIMUOVERE I
DUE DADI INDICATI
VF073 EDIZIONE N° 5: 12/06/2012
FAR Rubinetterie S.p.A. - www.far.eu
STELLANTRIEB “SMALL”
MONTAGEANLEITUNG
ART.3001 20 230 V
ART.3001 40 230 V
ART.3002 20 24 V
ART.3002 40 24 V
ART.3005 20 230 V
ART.3005 40 230 V
ART.3006 20 24 V
ART.3006 40 24 V
ART.3007 8 230 V
ART.3008 8 24 V
ARTIKEL
SPANNUNG
STROMVERBRAUCH
DREHWINKEL
DREHZEIT
DREHMOMENT
RAUMTEMPERATUR
SCHUTZGRAD
FARBE
3001 20
230V-50HZ
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GELB
3001 40
230V-50HZ
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GELB
3002 20
24V-50HZ
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GELB
3002 40
24V-50HZ
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GELB
3005 20
230V-50HZ
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GRÜN
3005 40
230V-50HZ
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GRÜN
3006 20
24V-50HZ
4,5 VA
90°
20 S
6 Nm
-10° + 50°C
IP54
GRÜN
3006 40
24V-50HZ
4,5 VA
90°
40 S
10 Nm
-10° + 50°C
IP54
GRÜN
3007 8
230V-50HZ
6 VA
90°
8 S
6 Nm
-10° + 50°C
IP54
GRAU
3008 8
24V-50HZ
6 VA
90°
8 S
6 Nm
-10° + 50°C
IP54
GRAU
1. BESCHREIBUNG DES STELLANTRIEBS
Der Stellantrieb mit Getriebemotor ermöglicht, ein Mischventil in völlig
automatischer Weise zu steuern. Das Auslösungssignal wird von einem
Thermostat oder einem ähnlichen Signalgeber mit "Ein-Aus"-Funktion
übernommen. Durch die Stellungsanzeige am Gehäuse lässt sich die
Stellung der Kugel ablesen.
Bevor Sie das Gerät installieren, prüfen Sie, ob der Antrieb in "offen"-
Stellung steht; Die Anzeige muss in die gleiche Richtung zeigen, in der
das Medium fließt. Der Schlitz im Spindelkopf des Gehäuses muss in der
gleichen Richtung wie der Zapfen des Motors ausgerichtet sein. Führen Sie
die Gewindebolzen in die Bohrungen des Flansches ein und ziehen Sie die
Muttern an. Der Antrieb kann mit allen Zonen-Ventilen kombiniert werden.
2. NUTZUNG DER HAND-NOTBETRIEB
Die Hand-Notbetrieb wird genutzt:
- um den Wasserfluss während Wartungsarbeiten zu
unterbrechen
- zur Kugelverstellung, wenn der Motor bereits installiert ist
- bei Stromausfall.
Um den Motor in die gewünschte Position zu bringen, gelbe
Taste gedrückt halten und gleichzeitig die Stellungsanzeige,
mit der Antriebswelle verbunden, um 90° im.
Gegenuhrzeigersinn drehen. Die normale
Wiederinbetriebnahme erfolgt automatisch.
3. ELEKTRISCHER ANSCHLUSS
Bevor die elektrische Verbindung vorgenommen wird, ist zu prüfen, ob der gewählte Stellantrieb mit der vorhandenen Netzspannung kompatibel
ist. Alle Verbindungen müssen von Fachleuten vorgenommen werden. Der Schaltplan (auch auf dem Stellantrieb selbst angegeben) muss
berücksichtigt werden. Das Strom muss unbedingt ausgeschaltet sein. Fehlerhafte Verbindungen können Schaden an Personen und an
den Stellantrieb selbst anrichten. Alle Modelle verfügen über einen Zusatz-Mikroschalter, d.h. einen spannungslosen Wechselkontakt, zur
Verbindung eines Signalgebers für die Niederspannung (max. 230V) und/oder für Benutzerkreise von geringer Absorption (max. 2A).
3-KABEL- VERBINDUNG: SCHALTUNG MIT RAUMTHERMOSTAT
5-KABEL- VERBINDUNG: SCHALTUNG MIT RAUMTHERMOSTAT UND PUMPENSTEUERUNG
Die Steuerung des Zonenventils durch den Stellantrieb erfolgt über die
Kabelverbindung mit dem Signalgeber. Das blaue Kabel wird mit dem
Neutralleiter verbunden, das braune und das schwarze Kabel werden
mit dem Raumthermostat verbunden. Führt das schwarze Kabel
Strom, wird das Ventil geöffnet. Wird das schwarze Kabel wieder
stromlos geschaltet, fährt das Ventil in die Ausgangsstellung zurück.
Ein eingebauter Mikroschalter, mit dem grauen und dem weißen
Kabel verbunden (freien Kontakt), unabhängig von der Schaltung
des Stellantriebs, ermöglicht die Parallelschaltung von mehreren
Stellantrieben und somit ein einziges Gerät zu steuern (z.B., eine
Pumpe oder die Kesselregelung). Zur Auslösung der Pumpe,
verbinden Sie das graue und das weiße Kabel an die 2 Klemmen, die
am (Kessel) zum Anschluss an die Thermostate zur Verfügung stehen.
1
2
3
N
5
6
7
INTERNE KLEMMENLEISTE
GRAU
WEISS
BLAU
BRAUN
SCHW
ARZ
SCHALTUNG
BESCHREIBUNG
MIKROSCHALTER
GEMEINSAMER KONTAKT
VERBINDUNG MIT DEM ZUSATZ-
MIKROSCHALTER
ÜBLICHERWEISE OFFENER
MIKROSCHALTER
VERBUNDEN MIT DEM ÜBLICHERWEISE
OFFENEN ZUSATZ-MIKROSCHALTER
SIGNALANZEIGE
BEI GEÖFFNETEM VENTIL, STROM AN DER
KLEMME VORHANDEN
NEUTRAL
VERBINDUNG MIT DEM NEUTRALLEITER
PHASE
VERBINDUNG MIT PHASE
ÖFFNET
BEI STROM AN DER SCHWARZEN KLEMME,
VENTIL OFFEN
SCHLIEßT
OHNE STROM AN DER SCHWARZEN
KLEMME, VENTIL GESCHLOSSEN
SIGNALANZEIGE
BEI GESCHLOSSENEM VENTIL, STROM AN
DER KLEMME VORHANDEN
N°
FARBE
1
GRAU
2
WEISS
3
-
N
BLAU
5
BRAUN
6
SCHWARZ
7
-
EU-RICHTLINIE 2002/96/EG BEZÜGLICH ABFALL VON ELEKTRISCHEN UND ELEKTRONISCHEN GERÄTEN
Nach der europäischen WEEE-Richtlinie 2002/96/EG (Abfall von elektrischen und elektronischen Geräten) ist eine
Entsorgung von allen WEEE Geräten als Hausmüll verboten. Die betreffenden Geräte sind getrennt zu entsorgen.
Für die einwandfreie Entsorgung der WEEE Geräte wenden Sie sich bitte an die zuständigen Behörden, die über das
betreffende Entsorgungsverfahren informieren. Bei Kauf eines neuen, identischen Geräts ist es zulässig, das Altgerät
zur Entsorgung dem Händler zu übergeben.
KONFORMITÄTSERKLÄRUNG
FAR Rubinetterie erklärt unter eigener Verantwortung, dass der Stellantrieb der folgenden EU-Richtlinien entspricht:
2004/108/CE und 2006/95/CE.
4. KUNDENDIENST
Bei technischen Schwierigkeiten vermeiden Sie bitte jeden direkten Eingriff und setzen Sie sich mit der Fa. FAR Rubinetterie S.p.A. Via
Morena, 20 – 28024 Gozzano (NO) Tel. +39.0322.94722 – Fax +39.0322.955332 in Verbindung.
Der Stellantrieb ist doppelt isoliert, daher ist die Erdung nicht notwendig.
MUTTERN
BEIDE GEWINDEBOLZEN
NICHT ENTFERNEN!
Art.3001- 3002- 3005- 3006-3007-3008
Art.3001- 3002- 3005- 3006-3007-3008
Achtung: kein Betrieb Der Einsatz in explosionsgefährdeten Umgebungen
ist nicht zulässig!
D
I