3.1.2
AES/EBU Input
The monitor has a balanced AES/EBU input on a XLR combo plug. The AES/EBU input is
selectable via the monitor control menu. The AES/EBU input complies with the IEC
60958 standard. 2 audio channels are carried over an IEC60958 stream. The desired
channel is selectable via the monitor control menu.
3.1.3
AES/EBU Output
The monitor has a balanced AES/EBU output on a XLR plug. The AES/EBU output
content is selectable via the monitor control menu. The AES/EBU output complies with
the IEC 60958 standard.
The typical use of the AES/EBU output is a signal loop-through to feed other monitors
with the same signal.
3.1.4
FAR Link Network
The FAR Link network allows for streaming of monitor control messages and a pair of
digital audio channels compliant with IEC60958 (AES/EBU like but on another medium).
3.1.4.1
Control Channel
The control channel allows the exchange of messages and data between the monitors
and/or the remote control devices (PC or dedicated remote control).
3.1.4.2
Digital audio input
The monitor can use a CAT5 cable on RJ45 FAR Link
TM
network plug to receive a digital
audio stream compliant with IEC60958. The Network digital audio input is selectable via
the monitor control menu. 2 audio channels are carried over IEC60958. The desired
channel is selectable via the monitor control menu.
The Network digital audio stream and the AES/EBU stream can run concurrently, making
4 digital audio channels simultaneously available to each monitor.
3.1.4.3
Digital audio output
The monitor can use a CTA5 cable on the RJ45 FAR Link
TM
network plug to transmit a
digital audio stream compliant with IEC60958. The Network digital audio output content
is selectable via the monitor control menu.
3.2
Operation Overview
The control panel at the speaker rear gives access to the basic configuration parameters
of the monitor. The menu items can be selected (displayed on the alphanumerical
screen) using the left and right keys (PREVIOUS / NEXT) while the parameter value is
changed using the up and down keys (+ / -).
The alphanumerical LCD displays the information on 2 lines. The first line shows the
selected parameter and its value. The second line gives the speaker status.
Figure 4: Display layout
The input signal field indicates the signal currently used by the monitor. When the
central button is pushed, the monitor is muted and the field shows “Mut”. In nominal
operation, the field can get the following values:
-
ANA to indicate that the analogue input is active
-
AES to indicate that the AES/EBU input is selected